Century HES80 Clearance to Combustibles, Hearth, Electric Specifications, Electrical Connection

Models: HES80

1 8
Download 8 pages 24.36 Kb
Page 5
Image 5
Clearance to Combustibles

Clearance to Combustibles

Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2” (51 mm) Sides . . . . . . . . . . . . . . . . . . . . . . . . . . . .6” (153 mm) Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0” (0 mm) Top . . . . . . . . . . . . . . . . . . . . . . . . . . . .24” (610 mm)

Hearth

A hearth is not mandatory, but is recommended for aesthetic purposes. We recommend a noncombustible hearth which does not obstruct heater openings.

Electric Specifications

Voltage . . . . . . . . . . . . . . . . . . . . . . . .120V AC/60Hz

Total Amps . . . . . . . . . . . . . . . . . . . . . . .12.20 Amps

Total Watts . . . . . . . . . . . . . . . . . . . . . . . .1460 Watts

Heater Ratings . . . . . . . . . . . . . . . . . . . .1300 Watts

Electrical Connection

A 15 Amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the appliance will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation.

The unit comes standard with a 6’ (1.8m) long three wire cord, exiting from the rear of the stove. Plan the installation to avoid the use of an extension cord. If an extension cord must be used, it must be a minimum 14AWG, three wire with grounding type plug connector and rated not less than 1875 Watts. The cord shall not be more than 20’ (6m) in length.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this stove if any part of it has been under water. Immediately call a qualified service tech- nician to inspect the stove and replace any part of the electrical system.

Fan Kit Installation

When installed, the heater must be elec- trically connected and grounded in accor- dance with local codes, or in th absence of local codes, with ANSI/NFPA No. 70.

NOTE: 110/120 electric power is required to operate blower (fan).

Be sure to leave sufficient excess wire in case minor adjustments are required.

Any electrical re-wiring of this fan must be done by a qualified electrician.

Turn off all power before installation.

CAUTION: Be careful not to touch or bend the flame generator.

1.Remove panel from back of pedestal

2.Install the fan through the opening at the back of the pedestal. Place fan assembly as far forward as possible, inserting long flange through slot in front panel. (Fig. 1)

Slot

ST824

Fig. 1 Insert flange through slot in front panel.

3.Use two screws provided to secure fan assembly to base of pedestal. (Fig. 2)

4.From front of unit, attach brass handle to front of fan assembly flange. (Fig. 3)

5.Plug in grounded service cord to a convenient wall receptacle.

6.Replace rear panel in pedestal.

S190006

5

Page 5
Image 5
Century HES80 Clearance to Combustibles, Hearth, Electric Specifications, Electrical Connection, Fan Kit Installation