Just how much airflow is required?
HVI recommends ventilation rates based on 8 air changes per hour. For most bathrooms this works out to 1 cfm per square foot of area, with a minimum of 50 cfm.
A bathroom less than 100 square feet:
Calculate 1 cfm per square foot of floor area. A minimum of 50 cfm is the required ventilation rate.
A bathroom larger than 100 square feet:
To calculate the proper ventilation rate, add the cfm requirement for each fixture; toilet 50 cfm, shower 50 cfm, bathtub 50 cfm, jetted tub 100 cfm.
Note: For proper sizing, the static pressure (SP) needs to be calculated. For typical applications, you may read from the .2” SP column for a selection.
Performance Data
MODELS | WATTS | AMPS | RPM | dBA |
|
| CUBIC FEET PER MINUTE |
|
| ||||
0”SP | .2”SP |
| .4”SP | .8”SP | 1.0”SP | 1.25”SP | 1.5”SP | ||||||
AXC100A | 55 | 0.57 | 1750 | 44 | 106 | 90 |
| 80 | 63 | 55 |
| 39 | - |
AXC100B | 85 | 0.69 | 2400 | 54 | 152 | 140 |
| 129 | 101 | 82 |
| 66 | 33 |
AXC150A | 80 | 0.75 | 2500 | 54 | 247 | 200 |
| 168 | 120 | 92 |
| 50 | - |
AXC200A | 72 | 0.72 | 2550 | 56 | 418 | 350 |
| 278 | 164 | 174 |
| 110 | 56 |
Helpful Tips
•AXC fan mounts easily to attic joists with the exclusive Continental Fan mounting bracket.
•Always use insulated duct in unheated spaces.
•When direct venting a shower, or if noise is a significant factor, use insulated flexible duct to reduce condensation and/or noise levels.
Dimensional Data
|
|
|
|
|
|
|
| D | d |
| a | B | WT | |||
MODELS |
| (in.) | (in.) |
| (in.) | (in.) | (lbs) | |||||||||
AXC100A | 9.5 |
| 3.9 | 1.0 | 8.3 | 6.5 | ||||||||||
AXC100B | 9.5 |
| 3.9 | 1.0 | 8.3 | 6.5 | ||||||||||
AXC150A | 9.5 |
| 5.8 | 1.0 | 8.3 | 6.5 | ||||||||||
AXC200A | 13.2 |
| 7.8 | 1.0 | 9.1 | 11.0 | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R
Available Accessories
A full range of accessories is available to suit each custom application.
Speed Controls | Dehumidistats | Digital Timers | Flexible Duct | Roof Caps |
|
|
|
|
|
Wall Caps
Continental Fan Manufacturing Inc.
203 Eggert Road
Buffalo, NY 14215
Tel:
Fax:
Distributed By:
Aeroflo Inc.