INSTALLATIONSTEP 6Install the Door Control
Locate door control within sight of the door at a
minimum height of 5 feet where small children cannot
reach, and away from moving parts of the door and
door hardware.The installation surface must be
smooth and flat. If installing into drywall (Fig. 1), drill
5/32" holes and use anchors provided. For pre-wired
installations (as in new home construction), it may be
mounted to a single gang box (Fig. 2). NOTE: After
installation, a green indicator light behind the cover
will indicate proper connection. If not lit, the Lock and
Light features will not function (reverse wires to
correct).
1. Strip 7/16" of insulation from one end of bell wire
and connect to the two screw terminals on back of
door control by color: white wire to 2 and white/red
wire to the 1 (Fig. 3).
2.Remove white cover (push bar) by gently prying at
slot in top of the cover with a small flat head
screwdriver.(Fig. 4). Fasten with 6ABx1-1/4"self-
tapping screws (drywall installation) or 6-32x1"
machine screws (into gang box) as follows:
• Drill and install bottom screw, allowing 1//8" to
protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Install top screw with care to avoid cracking plastic
housing. Do not overtighten.
• Insert bottom tabs and snap on cover. (To remove
cover after mounting, gently pry at top with paper
clip or small flat head screwdriver.)
NOTE: The push bar may stick if the door control is
not mounted on a smooth surface. If a click is not
heard when pressing the push bar, loosen the two
mounting screws and relocate the door control to a
smoother surface.
3.(Standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4.Strip 7/16" of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red. (Fig. 5).
5.Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label
in a prominent location on inside of garage
door.
NOTE: DO NOT connect the power and
operate the opener at this time. The trolley will
travel to the full open position but will not return
to the close position until the sensor beam is
connected and properly aligned. See Safety
Reversing Sensor Instructions beginning on page 17.
2
1
RED WHT
Bell Wire
Terminal
Screws
Bottom Mounting Hole
Top Mounting Hole
Dry Wall Anchors
Insulated
Staples
6AB x 1-1/4" Screw
(drywall installation)
6-32 x 1" Screw
(gang box installation)
HARDWARE SHOWN ACTUALSIZE
Figure 2
To Replace
Insert Bottom Tabs First
PRE-WIRED
INSTALLATION
24 Volt
Bell Wire
LOCK
LIGHT
LOCK
LIGHT
To Replace
Insert Bottom Tabs First
Figure 1 STANDARD
INSTALLATION
Single
Gang Box
Figure 3 MULTI-FUNCTION
DOOR CONTROL(BACK)
KG
1
3
9
7
5
KG
1
3
9
7
5
Figure 5
Red
Black
White
To release wire, push in tab
with screwdriver tip Door Control
Connections
Red BlackWhite
7/16"
Strip wire 7/16"
To prevent possible SERIOUS INJURYor DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLYto 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURYor DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet, and away
from all moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLYwhen it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYSkeep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.