MOUNTING AND WIRING THE SAFETY SENSORS

ïSlide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5).

ïFinger tighten the wing nuts.

ïRun the wires from both sensors to the opener. Use insulated staples to secure wire to wall and ceiling.

ïStrip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener quick-connect terminals. Twist like colored wires together. Insert wires into quick-connect holes: white to white and white/black to grey (Figure 6).

ALIGNING THE SAFETY SENSORS

ïPlug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct.

The sending eye amber indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required.

ïLoosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place.

ïLoosen the receiving eye wing nut and adjust sensor until it receives the senderís beam. When the green indicator light glows steadily, tighten the wing nut.

Figure 5

Wing Nut

Carriage Bolt

1/4"-20x1/2"

Lens

TROUBLESHOOTING THE SAFETY SENSORS

1.If the sending eye indicator light does not glow steadily after installation, check for:

ïElectric power to the opener.

ïA short in the white or white/black wires. These can occur at staples, or at opener connections.

ïIncorrect wiring between sensors and opener.

ïA broken wire.

2.If the sending eye indicator light glows steadily but the receiving eye indicator light doesnít:

ïCheck alignment.

ïCheck for an open wire to the receiving eye.

3.If the receiving eye indicator light is dim, realign either sensor.

NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The opener lights will blink 10 times. See page 16.

Connect Wire to

Quick-Connect Terminals

Figure 6

 

Finished

Bell Wire

Ceiling

Bell Wire

1. Strip wire 7/16"

(11 mm) 7/16"

(11 mm)

2. Twist like colored

wires together

3. Insert into appropriate terminals

Red White Grey

Sensor

Quick-Connect Terminals

 

Sensor

Invisible Light Beam

Protection Area

18