19
1/4"-20x1/2"
Carriage bolt Lens
Wing nut
Figure 4
TROUBLESHOOTING THE SAFETY SENSORS
1. If the sending eye indicator light does not glow
steadily after installation, check for:
• Electric power to the opener.
• A short in the white or white/black wires.These
can occur at staples, or at opener connections.
• Incorrect wiring between sensors and opener.
• A broken wire.
2. If the sending eye indicator light glows steadily but
the receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
3.If the receiving eye indicator light is dim, realign
either sensor.
NOTE: When the invisible beam path is obstructed or
misaligned while the door is closing, the door will
reverse.If the door is already open, it will not close.
The opener lights will blink 10 times. (If bulbs are not
installed, 10 clicks can be heard.) See page 17.
Invisible Light Beam
Protection Area
Sensor
Sensor
Connect Wire to
Opener Quick-Connect Terminals
Bell Wire
Bell Wire Finished
Ceiling
Red
Black
White
Quick-Connect Terminals
Strip wire 7/16"
7/16"
Sensor
Connections
Red BlackWhite
Figure 5
MOUNTING AND WIRING THE SAFETY SENSORS
• Slide a 1/4"-20x1/2" carriage bolt head into the slot
on each sensor. Use wing nuts to fasten sensors to
brackets, with lenses pointing toward each other
across the door. Be sure the lens is not obstructed
by a bracket extension (Figure 4).
• Finger tighten the wing nuts.
• Run the wires from both sensors to the opener.Use
insulated staples to secure wire to wall and ceiling.
• Strip 7/16" of insulation from each set of wires.
Separate white and white/black wires sufficiently to
connect to the opener quick-connect terminals: white
to white and white/black to black (Figure 5).
ALIGNING THE SAFETY SENSORS
• Plug in the opener. The indicator lights in both the
sending and receiving eyes will glow steadily if
wiring connections and alignment are correct.
The sending eye orange indicator light will glow
regardless of alignment or obstruction. If the green
indicator light in the receiving eye is off, dim, or
flickering (and the invisible light beam path is not
obstructed), alignment is required.
• Loosen the sending eye wing nut and readjust,
aiming directly at the receiving eye. Lock in place.
• Loosen the receiving eye wing nut and adjust sensor
until it receives the sender’s beam. When the green
indicator light glows steadily, tighten the wing nut.