MOUNTING AND WIRING THE SAFETY

REVERSING SENSORS

• Slide a 1/4"-20x1/2" carriage bolt head into the slot

on each sensor. Use wing nuts to fasten sensors to

brackets, with lenses pointing toward each other

across the door. Be sure the lens is not obstructed

by a bracket extension (Figure 5).

• Finger tighten the wing nuts. 

• Run the wires from both sensors to the opener. Use

insulated staples to secure wire to wall and ceiling. 

• Strip 1/4" (6 mm) of insulation from each set of

wires. Separate white and white/black wires

sufficiently to connect to the opener terminal

screws: white to 2 and white/black to 3 (Figure 6).

ALIGNING THE SAFETY REVERSING SENSORS

• Plug in the opener. The indicator lights in both the

sending and receiving eyes will glow steadily if

wiring connections and alignment are correct.

The sending eye amber indicator light will glow

regardless of alignment or obstruction. If the green

indicator light in the receiving eye is off, dim, or

flickering (and the invisible light beam path is not

obstructed), alignment is required.

• Loosen the sending eye wing nut and readjust,

aiming directly at the receiving eye. Lock in place.

• Loosen the receiving eye wing nut and adjust

sensor until it receives the sender’s beam. When

the green indicator light glows steadily, tighten the

wing nut.

TROUBLESHOOTING THE SAFETY REVERSING

SENSORS

1. If the sending eye indicator light does not glow

steadily after installation, check for:

• Electric power to the opener.

• A short in the white or white/black wires. These

can occur at staples, or at terminal connections.

• Incorrect wiring between sensors and opener.

• A broken wire.

2. If the sending eye indicator light glows steadily but

the receiving eye indicator light doesn’t:

• Check alignment.

• Check for an open wire to the receiving eye.

3. If the receiving eye indicator light is dim, realign

either sensor.

NOTE: When the invisible beam path is obstructed

or misaligned while the door is closing, the door will

reverse. If the door is already open, it will not close.

The opener lights will blink 10 times. (If bulbs are not

installed, 10 clicks can be heard.) See page 21.

Invisible Light Beam

Protection Area

Safety Reversing Sensor

Safety Reversing Sensor

Connect Wire to

Opener Terminal Screws

Bell Wire

Finished Ceiling

OPENER TERMINAL SCREWS

Sensor

Connections

Door Control

Connections

(dotted line)

1

2

3

Bell Wire

Figure 6

Page 23
Image 23
Open full-size image