Planning (Continued)
WARNING
ONE-PIECE DOOR INSTALLATIONS
• Generally, a one-piece door does not require
reinforcement. If your door is lightweight, refer to
the information relating to sectional doors in
Installation Step 11.
• Depending on your door’s construction, you may
need additional mounting hardware for the door
bracket (Step 11).
Without a properly working safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
• The gap between the bottom of the garage door and
the floor MUST NOT exceed 1/4" (6 mm). Otherwise,
the safety reversal system may not work properly.
• The floor or the garage door MUST be repaired to
eliminate the gap.
CAUTION
FINISHED CEILING
ONE-PIECE DOOR WITHOUT TRACK
Support bracket
& fastening
hardware is required.
See page 17.
Slack in Chain Tension
is Normal When
Garage Door is Closed
Header
Wall
Motor Unit
Wall-mounted
Door
Control
Access
Door
CLOSED POSITION
Idler
Pulley Bracket
Trolley
Header
Bracket
Rail
Door
Bracket
Safety
Reversing Sensor
Gap between floor and bottom
of door must not exceed 1/4" (6 mm).
Safety
Reversing Sensor
Header
Wall
Garage
Door
Straight
Door
Arm
Curved
Door
Arm
Emergency
Release
Rope
& Handle
ONE-PIECE DOOR WITH TRACK
CLOSED POSITION
Header
Wall
Access
Door
Header
Bracket
Wall-
Mounted
Door
Control
Garage
Door
Safety Reversing
Sensor
Safety Reversing
Sensor
Gap between floor
and bottom of door
must not exceed 1/4" (6 mm)