Bell Wire |
|
| Diagnostics |
| Located On |
| Motor Unit |
| LED or |
| Diagnostic |
| LED |
Safety Reversing Sensor | “Learn” |
Button |
Diagnostic Chart
Installed
Safety Reversing
Sensor
Your garage door opener is programmed with
| 1 FLASH |
|
|
|
|
|
|
|
| Symptom: One or both of the indicator lights on the safety reversing sensors | ||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| do not glow steady. | ||
Safety reversing sensors | ||||||||||||
|
|
| • Inspect sensor wires for a short (staple in wire), correct wiring polarity | |||||||||
wire open (broken or |
|
|
| |||||||||
|
|
|
| (black/white wires reversed), broken or disconnected wires, replace/attach | ||||||||
disconnected). |
|
|
|
| ||||||||
|
|
|
| as needed. | ||||||||
| OR |
|
|
|
| |||||||
|
|
|
| • Disconnect all wires from back of motor unit. | ||||||||
|
|
|
|
|
|
|
|
|
| • | Remove sensors from brackets and shorten sensor wires to | |
2 | FLASHES |
|
|
| ||||||||
|
|
|
| from back each of sensor. | ||||||||
|
|
|
|
|
|
|
|
|
|
| ||
Safety reversing sensors |
|
|
| • | Reattach sending eye to motor unit using shortened wires. If sending eye | |||||||
wire shorted or black/white |
|
|
|
| indicator light glows steadily, attach the receiving eye. | |||||||
wire reversed. |
|
|
|
| ||||||||
|
|
| • Align sensors, if the indicator lights glow replace the wires for the sensors. If | |||||||||
| 3 FLASHES |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| the sensor indicator lights do not light, replace the safety sensors. | |
3 | FLASHES |
|
|
|
|
|
| |||||
|
|
|
|
| Symptom: LED is not lit on door control. | |||||||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
| • Inspect door control/wires for a short (staple in wire), replace as needed. | ||
Door control or wire shorted. |
|
|
| |||||||||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| • Disconnect wires at door control, touch wires together. If motor unit activates, | ||
|
|
|
|
|
|
|
|
|
|
| replace door control. | |
|
|
|
|
|
|
|
|
|
| • If motor unit does not activate, disconnect door control wires from motor unit. | ||
|
|
|
|
|
|
|
|
|
|
| Momentarily short across red and white terminals with jumper wire. If motor | |
|
|
|
|
|
|
|
|
|
|
| unit activates, replace door control wires. | |
4 | FLASHES |
|
|
|
|
|
| Symptom: Sending indicator light glows steadily, receiving indicator light is | ||||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
| dim or flashing. | ||
Safety reversing sensors |
|
|
| |||||||||
|
|
| • Realign receiving eye sensor, clean lens and secure brackets. | |||||||||
slightly misaligned |
|
|
| |||||||||
(dim or flashing LED). |
|
|
| • Verify door track is firmly secured to wall and does not move. | ||||||||
5 | FLASHES |
|
|
|
|
|
|
| Symptom: Motor has over heated; the motor unit does not operate or trolley is | |||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
| stuck on stop bolt = Motor unit hums briefly; RPM Sensor = Short travel | ||
Motor overheated or possible |
|
|
|
| ||||||||
|
|
|
|
| ||||||||
RPM sensor failure. Unplug |
|
|
| • Unplug unit to reset. Try to operate motor unit, check diagnostic code. | ||||||||
to reset. |
|
|
| • If it is still flashing 5 times and motor unit moves | ||||||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| RPM sensor. | |
|
|
|
|
|
|
|
|
|
| • | If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and | |
|
|
|
|
|
|
|
|
|
|
| retry. If motor unit still will not operate replace logic board. | |
6 | FLASHES |
|
|
|
| Symptom: Motor unit doesn’t operate. | ||||||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
| • Replace logic board because motor rarely fails. | ||
Motor Circuit Failure. Replace |
|
|
| |||||||||
|
|
|
|
| ||||||||
Receiver Logic Board. |
|
|
|
| 30 | |||||||
|
|
|
|
|
|
|
|
|
|
|