MOUNTING AND WIRING THE SAFETY REVERSING

Figure 4

 

SENSORS

 

 

 

Wing Nut

 

 

 

• Slide a 1/4"-20x1/2" carriage bolt head into the slot on

 

 

 

1/4"-20

 

each sensor. Use wing nuts to fasten sensors to

 

 

 

 

 

 

brackets, with lenses pointing toward each other across

 

 

 

 

 

 

the door. Be sure the lens is not obstructed by a bracket

Carriage Bolt

 

 

 

 

 

 

 

 

extension (Figure 4).

 

 

 

 

1/4"-20x1/2"

Finger tighten the wing nuts.

 

 

 

Lens

 

 

 

 

 

Run the wires from both sensors to the opener. Use

TROUBLESHOOTING THE SAFETY REVERSING

 

insulated staples to secure wire to wall and ceiling.

 

SENSORS

Strip 7/16" (11 mm) of insulation from each set of wires.

1. If the sending eye indicator light does not glow steadily

 

Separate white and white/black wires sufficiently to

 

after installation, check for:

 

connect to the opener quick-connect terminals. Twist like

 

• Electric power to the opener.

 

colored wires together. Insert wires into quick-connect

 

• A short in the white or white/black wires. These can

 

holes: white to white and white/black to grey (Figure 5).

ALIGNING THE SAFETY REVERSING SENSORS

occur at staples, or at opener connections.

• Incorrect wiring between sensors and opener.

Plug in the opener. The indicator lights in both the

• A broken wire.

 

sending and receiving eyes will glow steadily if wiring

 

2. If the sending eye indicator light glows steadily but the

 

connections and alignment are correct.

The sending eye amber indicator light will glow regardless

receiving eye indicator light doesn't:

• Check alignment.

of alignment or obstruction. If the green indicator light in

the receiving eye is off, dim, or flickering (and the invisible

• Check for an open wire to the receiving eye.

light beam path is not obstructed), alignment is required.

3. If the receiving eye indicator light is dim, realign either

Loosen the sending eye wing nut and readjust, aiming

sensor.

 

directly at the receiving eye. Lock in place.

NOTE: When the invisible beam path is obstructed or

Loosen the receiving eye wing nut and adjust sensor

misaligned while the door is closing, the door will reverse.

 

until it receives the sender’s beam. When the green

If the door is already open, it will not close. The opener

 

indicator light glows steadily, tighten the wing nut.

lights will blink 10 times. (If bulbs are not installed, 10

 

 

clicks can be heard.) See page 15 .

 

Connect Wire to

 

 

Figure 5

Opener Quick-Connect Terminals

 

 

 

 

 

Bell Wire

Finished

 

 

Ceiling

 

 

 

1.

Strip wire 7/16"

 

Bell Wire

(11 mm)

7/16"

 

(11mm)

 

 

 

 

2.

Twist like colored

 

 

wires together

 

3.

Insert into

 

 

 

appropriate terminals

Red White Grey

Quick-Connect Terminals

Safety Reversing Sensor

 

Invisible Light Beam

Safety Reversing Sensor

Protection Area

17