Operation of Your Opener

Activate the opener with any of the following:

•The Remote Control Transmitter. Hold push button down until the door starts to move.

•The Door Control. Hold push bar or button down until the door starts to move.

•The Outside Keylock or Keyless Entry. (See Accessories)

When the opener is activated with the safety reversing sensor installed and correctly aligned:

WARNING

Weak or broken springs could allow an open door to fall (either rapidly or unexpectedly), resulting in serious injury, death or property damage. If possible, use the manual release rope and handle only when door is fully closed.

1.

If open, the door will close. If closed, the door will

 

open.

2.

If closing, the door will reverse.

3.

If opening, the door will stop (allowing space for

 

entry and exit of pets and for fresh air).

4.

If the door has been stopped in a partially open

 

position, it will close.

5.

If obstructed while closing, the door will reverse.

6.

If obstructed while opening, the door will stop.

7.

The garage door will reverse in the closing cycle

 

when the invisible beam is broken. If fully open,

 

the door will not close when the beam is broken.

Trolley Release Arm

Trolley

Manual

 

Release Handle

 

(Pull Down)

NOTICE

Manual disconnect

position

To open the door manually:

The door should be fully closed if possible. Pull down on the manual release handle and lift the door manually. To reconnect the door to the opener, press the Door Control push bar.

The sensor has no effect in the opening cycle.

If the sensor is not installed, or is not aligned correctly, the door won't close from any remote transmitter. You can close the door with the Door Control, the Outside Keylock, or Keyless Entry, however, if you activate them until down travel is complete. If you release them too soon, the door will reverse.

The opener lights will blink for 5 seconds when the safety reversing sensor causes the door to reverse.

Opener Lights will turn on under the following conditions: When the opener is initially plugged in; when the power is interrupted; when the opener is activated. They will turn off automatically after 4-1/2 minutes or provide constant light when the Light feature is activated. Bulb size is 75 watts maximum.

The lockout feature prevents the trolley from reconnecting automat- ically. Pull the manual release handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary. To disengage the Lockout Feature, pull the manual release handle straight down. The trolley will reconnect on the next UP or DOWN operation.

 

Trolley

 

Release Arm

Trolley

 

Manual

 

Release Handle

 

(Pull Down & Back

 

Towards Opener)

NOTICE

 

Lockout position

Operation of the Multi-Function Door Control Panel

Lighted Push Bar:

Press to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening.

Light Feature:

Press the Light button. If the opener light is off, it will turn on.

If the opener light is on, (even in the 4-1/2 minute automatic cycle) it will turn off.

But if you use the Light button to turn the light(s) on and then activate the opener, the light(s) will turn off after 4-1/2 minutes.

The Light feature will not control the opener lights when the door is in motion.

Lock Feature:

Designed to prevent operation of the door from portable remote controls. However, the door will open and close from the Door Control push bar and from the Outside Keylock and the Keyless Entry Accessories.

To activate: Press and hold the Lock button for 2 seconds. The push bar indicator light will flash as long as the Lock is on.

To turn off: Press and hold the Lock button again for 2 seconds. The push bar indicator light will stop flashing. Normal operation will resume. The Lock feature will also turn off whenever the "Smart" button on the opener end panel is activated.

32