I N S T A L L A T I O N
CONTROL ARM ASSEMBLY (SW470)
1.Set the control arm stop on the operator in the positions appropriate for the installation (Figure 1).
2.Install the arm channel to the hub assembly to the operator output shaft.
3.Secure the arm channel to arm hub with
4.Assemble extension arm to control arm. Be sure to keep the extension arm with
CAUTION
If the arm stop is installed incorrectly, the gate will be prevented from opening and damage to the operator may result!
Figure 1 |
| Close Stops |
|
| |
|
|
|
|
|
|
|
|
|
Left hand | Right hand |
installation | installation |
Figure 2
Black Plastic
Knob
Arm Channel
Housing
SW470 Parallel to Fence
Close Stops
“L.H.”“R.H.”
SW470 Perpendicular to Fence
Figure 3
Hub
Assembly
GATE BRACKET INSTALLATION (SW470)
Eccentric stop during installation of gate plate
Installation Detail
36" | Hinge Pin | |
| Eccentric stop (operating position | |
Gate | after adjustment). Arm must | |
swing approximately 2 degrees | ||
Plate | ||
past straight position (See detail) | ||
| ||
Crank Extension |
| |
Extension arm | NOTE: Dotted line indicates | |
installation detail | straight arm position |
1.Install gate bracket (supplied) or install an angle (2" x 2" x 1/4" by others) horizontally on gate, at the same height as the top surface of the control arm extension (see figure to the right).
2.Adjust the eccentric stop as shown so that the wide area of the eccentric stop is against the arm. Be sure that the control arm and actuator are in a straight line. Install the gate bracket and if required install an angle (for SW490 2" x 2" x 1/4" by others) at the appropriate point on the gate in reference to gate hinge pin.
NOTE: As an alternative, (2)
Model SW470
Top of gate bracket should be mounted 1/2" higher than top of arm channel
Arm Channel
Gate
Bracket
Gate
12