The hot water system should be a
gravity circuit and must be correctly
vented as shown in Fig. 4.
The steel boiler together with a
double feed indirect hot water storage
cylinder to BS:1566 part 1 should be
used in most situations, unless the
appliance is to be fitted in asoft
water area in which case the stainless
steel boiler maybe used with adirect
hot water cylinder.
All pipework in the primarycircuit
must be 28mm diameter and the flow
pipe must rise continuously from the
boiler to the open vent.
If an indirect cylinder is used then
the primarycircuit should be filled
with asuitable inhibitor to prevent
the build up of scale and corrosion.
FITTING THEOPTIONAL ADD-INBOILERThe boiler replaces the rear firebrick.
On the Country8the boiler also
replaces the throat plate, on the
Country12 aspecial throat plate,
(part no. 010/BV35), is required.
Beforefitting the boiler, remove the
front firebars, the side and back fire
plates, the throat plate and the rear
firebrick. Knock out the knock-outs
for the boiler tappings in the back of
the firebox.
Remove the backnuts and fibre
washers from the boiler tappings and
fit the boiler into the appliance. Place
the fibre washers over the tappings
on the outside of the appliance and fit
the backnuts, ensuring that the boiler
is held tightly against the rear inside
face of the appliance and that the top
edge of the boiler is level or runs
uphill to the flow tapping.
Gaps between the boiler and the
firebricks should be filled with fire
cement. Replace the back fireplate,
the side fireplates and the front
firebar. On the Country12, fit the
new throat plate.
Connect the boiler to the heating
system ensuring that the flow pipe
rises from the boiler. Fill the system
with water and check for leaks.
CONNECTIONS TOFLUESThereare several ways of connecting
the stove to the flue. These are
illustrated in figures 5to 8.
If the vertical rear flue connector is
used and no boiler is fitted then the
Soot Door
in Side or Rear
Of Chimney
Register Plate
With Soot Door
Soot Door
Alternative
Positions
Register Plate
Soot Door
With Soot Door
Alternative
Positions
Fig. 7. Horizontal Register Plate
With Top Flue Connection
Fig. 6. Horizontal Register Plate
With Rear Flue Connection
Fig 5. Vertical Register Plate
With Bricked Up Fireplace
Register Plate
Fig. 4. Typical Gravity Hot Water System
Drain Cock at Lowest Point
Drain Cock
Gravity Return 28mm
Gravity Flow 28mm
Indirect Hot Water Cylinder
Cold Water Tank
22mm Open Vents
Overflow
Domestic Hot Water Draw Off
Overflow
Feed and Expansion Tank
Page 8