General Troubleshooting

General Troubleshooting

Symptom

Solution(s)

 

 

No Power

Check mains power.

 

Check external fuse.

 

Check internal fuse.

No fog output

Check fluid level.

 

Check remote.

 

If using wireless, check batteries.

 

If using wireless, check dipswitches on receiver.

Breaker/Fuse keeps blowing

Possible electrical short. Contact Chauvet or a Chauvet

 

Dealer/distributor for further instruction.

Low fog output

Run a cleaning solution through the fog machine.

 

Check that the fog machine is plugged into the correct voltage.

Fog machine is not heating up

Check the external fuse.

 

Check the internal fuse.

 

Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor

 

for further instruction.

Remote does not work

Make sure connector is firmly connected to device.

 

Try using another controller. Possible bad controller.

 

Check the internal fuse.

 

Check the external fuse.

Fluid indicator states no fog, but

Try resetting the fog machine by turning the power off, and then on

the container if full.

again.

 

Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor

 

for further instruction.

If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location listed below.

Contact Information

World Headquarters

 

United Kingdom & Ireland

CHAUVET®

 

 

CHAUVET® Europe Ltd.

General Information

 

General Information

Address:

5200 NW 108th Avenue

Address:

Unit 1C

 

Sunrise, FL 33351

 

Brookhill Road

Voice:

(954)

929‐1115

 

Pinxton, Nottingham, UK

Fax:

(954)

929‐5560

 

NG16 6NT

Toll free:

(800)

762‐1084

Voice:

+44 (0)1773 511115

Technical Support

 

Fax:

+44 (0)1773 511110

Voice:

(954)

929‐1115 (Press 4)

Email: uktech@chauvetlighting.com

Fax:

(954)

756‐8015

 

 

World Wide Web

 

World Wide Web

www.chauvetlighting.com

www.chauvetlighting.co.uk

Hurricane™ 1100 User Manual

11

September 7, 2011

Page 11
Image 11
Chauvet 1100 General Troubleshooting, Contact Information, World Headquarters, United Kingdom & Ireland, Technical Support