Ovation™ C-640FC QRG

 

AC Power

This product has an auto-ranging power supply that can work with an input

 

voltage range of 100-240 VAC, 50/60 Hz.

 

 

Power Linking

You can link up

to 9 Ovation™

C-640FC products

at 120 VAC or

 

18 at 230 VAC. Never exceed this number. Power linking cords can be

 

purchased separately.

 

 

 

AC Plug

 

 

 

 

Connection

Wire (U.S.)

Wire (Europe)

Screw Color

 

AC Live

Black

Brown

Yellow/Brass

 

AC Neutral

White

Blue

Silver

 

AC Ground

Green/Yellow

Green/Yellow

Green

Replacing the

1. Disconnect this product from power.

 

 

Fuse

2. Using a Phillips #2 head screwdriver, unscrew the fuse holder cap

 

from the housing.

 

 

 

3.Remove blown fuse and replace with a good fuse of the same type and rating.

4.Screw the fuse holder cap back in place and reconnect power.

DMX Linking The Ovation™ C-640FC will work with a DMX controller using a regular DMX serial connection. A DMX Primer is available from www.chauvetpro.com.

DMX Connection The Ovation™ C-640FC uses a regular DMX data connection for its DMX personalities: TOUR, TR16, ARC.1, AR1.D, ARC.2, ARC.3, AR3.D, AR3.S, PIX1, PIX3, PX16,and HSV. See the User Manual to connect and configure for DMX operation.

Note: For optimum control of the 16-bit dimming channels in the TR16 personality, be sure that the dimming curve in SET > DIMX is set to OFF.

Master/Slave The Ovation™ C-640FC uses the DMX data connection for its Master/Slave Connection mode. See the User Manual to connect and configure for Master/Slave

operation.