RECEPTACLE DETAILS

The following receptacle details are to aid in identifying mating plugs. Use this chart and compare to your genset to determine which receptacle(s) you have. Note the NEMA configuration and use this to purchase the correct mating plug.

NEMA 5-20R

NEMA L5-30R

NEMA L6-30R

NEMA L6-20R

125V - 20A

125V - 30A

250V - 30A

250V - 20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEMA 14-50R

NEMA L14-20R

NEMA L14-30R

125/250V - 50A

125/250V - 20A

125/250V - 30A

LOADING YOUR GENERATOR SET

With reference to the Receptacle details section, please review the power receptacles fitted to your generator. The actual load that may be pulled from each receptacle is driven by the circuit breaker rating and the generator rating. DO NOT

EXCEED THE INDIVIDUAL RECEPTACLE RATINGS AS SHOWN IN THE AMPERAGE RATE TABLE. DO NOT EXCEED THE TOTAL GENERATOR RATING SHOWN IN TABLE 2 PERFORMANCE SPECIFICATIONS. All generator units are equipped with a “PUSH TO RESET” Circuit Breaker.

AMPERAGE RATE TABLE

Model/

NEMA 5-20R

NEMA L5-30R

NEMA L14-30R

NEMA L6-30R

NEMA 14-50R

NEMA L6-20R

NEMA L14-20R

SKU

120V – Duplex

120V Twistlock

125V/250V

250V Twistlock

125V/250V

250V

125V/250V

 

 

 

Twistlock

 

Straight Blade

Twistlock

Twistlock

39461

20Amps

30Amps

30Amps

30Amps

N/A

N/A

N/A

39982

15Amps

30Amps

30Amps

25Amps

35Amps

N/A

N/A

39984

20Amps

30Amps

30Amps

30Amps

40Amps

N/A

N/A

40423

20Amps

30Amps

30Amps

30Amps

N/A

N/A

N/A

40814

20Amps

20Amps

N/A

20Amps

N/A

20Amps

20Amps

40827

20Amps

30Amps

30Amps

30Amps

45Amps

N/A

N/A

42723

20Amps

N/A

20Amps

N/A

N/A

N/A

20Amps

42724

20Amps

20Amps

N/A

20Amps

N/A

20Amps

20Amps

42725

20Amps

N/A

20Amps

N/A

N/A

N/A

20Amps

42726

20Amps

30Amps

30Amps

30Amps

N/A

N/A

N/A

42727

15Amps

30Amps

30Amps

25Amps

35Amps

N/A

N/A

42728

20Amps

30Amps

30Amps

30Amps

40Amps

N/A

N/A

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS AND WIRING DIAGRAM(S) IN THIS MANUAL AS A REFERENCE TOOL ONLY. NIETHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT; IN FACT THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. PARTS MY CHANGE OR VARY FROM THOSE SHOWN.

8

Page 8
Image 8
Chicago Electric 42728, 42727, 40814, 42723, 42724, 42725 Receptacle Details, Loading Your Generator SET, Amperage Rate Table