SAFETY

Grounding Instructions

TO PREVENT ELECTRIC SHOCK AND DEATH FROM INCORRECT GROUNDING WIRE CONNECTION READ AND FOLLOW THESE INSTRUCTIONS:

110-120 V~ Double Insulated Tools: Tools with Two Prong Plugs

SETUP

Outlets for 2-Prong Plug

Miter Saw Safety Warnings

1.To reduce the risk of electric shock, double insulated equipment has a polarized plug

(one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

2.Double insulated tools may be used in either of the 120 volt outlets shown in the preceding illustration.

(See Outlets for 2-Prong Plug.)

OPERATION

MAINTENANCE

For Your Own Safety Read Instruction

Manual Before Operating Miter Saw

1.Wear eye protection.

2.Keep hands out of path of saw blade.

3.Do not operate saw without guards in place.

4.Do not perform any operation freehand.

5.Never reach around saw blade.

6.Turn off tool and wait for saw blade to stop before moving workpiece or changing settings.

7.Disconnect power before changing blade or servicing.

8.To reduce risk of injury, return carriage to the full rear position after each crosscut operation.

9.Return all guards to original position if any are moved during blade replacement. Check all guards for proper operation after service.

10.The lock down pin is to be used only to lock the head in place for carrying and storage. It is not to be used for any cutting operation.

11.DANGER! Coasting Cutting Tool Can Be Dangerous – Apply brake immediately to stop cutting tool when the switch is turned off.

12.The torque developed during braking may loosen the blade-retaining nut/bolt. The blade retaining nut/bolt should be checked periodically and tightened if necessary, especially after braking.

13.Always use blades with correct size and shape (diamond versus round) of arbor holes. Blades that do not match the mounting hardware of the saw will run eccentrically, causing loss of control.

14.Never use damaged or incorrect blade washers or bolt. The blade washers and bolt were specially designed for your saw, for optimum performance and safety of operation.

15.Do not use to cut logs, tree limbs, or uneven lumber.

16.Wet lumber, green (unseasoned) lumber, and pressure treated lumber all have an increased potential for kickback and should only be cut with a blade for cutting that lumber type. Wear a NIOSH- approved respirator and have appropriate ventilation whenever cutting pressure treated lumber.

17.Do not use blades made from high-speed steel, abrasive blades, metal-cutting blades or masonry- cutting blades. The guards of this saw are not designed to protect against the failure of such blades.

18.Blades must be rated to at least the maximum speed marked on the tool.

19.DO NOT OPERATE WITH ANY GUARD DISABLED, DAMAGED, OR REMOVED. Moving guards must move freely and close instantly.

20.The use of accessories or attachments not recommended by the manufacturer may result in a risk of injury to persons.

21.When servicing use only identical replacement parts.

Page 4

For technical questions, please call 1-800-444-3353.

Item 69684

Page 4
Image 4
Chicago Electric 69684 owner manual Miter Saw Safety Warnings, Grounding Instructions, Outlets for 2-Prong Plug

69684 specifications

The Chicago Electric 69684 is a portable generator renowned for its reliable performance and essential features tailored for both home and outdoor use. This generator is particularly popular among DIY enthusiasts, campers, and homeowners looking for a dependable backup power solution during outages.

One of the standout features of the Chicago Electric 69684 is its robust 8750 watts peak output and 7000 watts running output, which provide ample power for various electrical devices. This makes it suitable for powering essential home appliances, tools, and recreational equipment. The generator is equipped with a 420cc OHV engine that promises durability and fuel efficiency, ensuring it operates effectively under demanding conditions.

The design of the Chicago Electric 69684 emphasizes user-friendliness and portability. Weighing approximately 150 pounds, it comes with built-in wheels and a foldable handle, enabling easy transport and maneuverability, whether you are moving it around the home or taking it on outdoor adventures. Its compact size allows for easy storage in garages or sheds without taking up too much space.

The generator features a durable steel frame that enhances its longevity and withstands rugged environments. Moreover, its low oil shutdown technology protects the engine, ensuring longevity and minimizing maintenance efforts. This feature automatically turns off the generator when oil levels are too low, preventing damage and encouraging responsible fuel management.

Users will appreciate the multiple outlets available on the Chicago Electric 69684. It includes standard 120V household outlets as well as 120/240V twist-lock outlets, making it versatile for various applications. The inclusion of a circuit breaker also helps protect connected devices from overloading, adding an extra layer of safety.

The noise level of the Chicago Electric 69684 is comparable to that of other generators in its class, making it a practical choice for residential areas. Although it generates a significant amount of power, it operates at a relatively low decibel level, allowing users to enjoy a quieter environment during usage.

Additionally, the generator is designed with fuel efficiency in mind, allowing for extended run times on a single tank. This feature is particularly advantageous for users who require consistent power without frequent refueling interruptions.

In conclusion, the Chicago Electric 69684 portable generator stands out with its powerful performance, user-friendly design, and safety features, making it a valuable addition for anyone in need of reliable backup power or outdoor electrical supply. Its blend of durability, efficiency, and portability ensures that it meets a wide range of power needs effectively.