Chicago Electric 96698 Troubleshooting, Problem Possible Causes Likely Solutions

Models: 96698

1 51
Download 51 pages 11.98 Kb
Page 19
Image 19

Troubleshooting

Problem

 

Possible Causes

 

Likely Solutions

Tool will not

1.

No power at outlet.

1.

Check power at outlet.

start

2.

Cord not connected.

2.

Check that cord is plugged in.

Tool operates

1.

Low power supply or improper

1.

Check power supply and power cords.

sporadically or

 

extension cords.

 

 

at low power

2.

Worn or cracked Carbon Brushes.

2.

Check Carbon Brushes. Replace if damaged

 

 

 

 

or worn.

Wood burns at

1.

Dirty Blade.

1.

Clean Blade using blade cleaner or mineral

ends when cut

 

 

 

spirits.

 

2.

Material is binding.

2.

Check position of work material on Table.

 

 

 

 

Material must be flat, flush against Fence

 

 

 

 

and supported on ends.

Material frays

1.

Finished side is down

1.

Always have finished side of material up or

or chips out.

 

 

 

facing you. Bottom and back side are prone

 

 

 

 

to chip out.

 

2.

Blade is chipped or dull.

2.

Check for damaged teeth. Sharpen or

 

 

 

 

replace blade.

 

3.

Blade is inappropriate for

3.

Check blade manufacturer’s

 

 

material.

 

recommendations for material being cut. For

 

 

 

 

cross cutting hard wood and for precision

 

 

 

 

cuts use a thin kerf blade with 60 or more

 

 

 

 

teeth.

 

4.

Material is unsupported.

4.

Use a thin piece of sacrificial material, such

 

 

 

 

as 1/4” plywood, underneath or behind the

 

 

 

 

material to support the edges of the material

 

 

 

 

as it is being cut.

Blade binds

1.

Material is misaligned on the saw

1.

Material must be flat on table, flush against

slowing or

 

or ends are not supported.

 

the fence and supported on both ends.

stopping saw.

2.

Material is wet, contaminated or

2.

Check condition of material and check

 

 

inappropriate blade is being used.

 

compatibility of blade to material.

Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.

PLEASE READ THE FOLLOWING CAREFULLY

The manufacturer and/or distributor has provided the parts list and assembly diagram in this manual as a reference tool only. Neither the manufacturer or distributor makes any representation or warranty of any kind to the buyer that he or she is qualified to make any repairs to the product, or that he or she is qualified to replace any parts of the product. In fact, the manufacturer and/ or distributor expressly states that all repairs and parts replacements should be undertaken by certified and licensed technicians, and not by the buyer. The buyer assumes all risk and liability arising out of his or her repairs to the original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto.

SKU 96698

For technical questions, please call 1-800-444-3353.

Page 19

Page 19
Image 19
Chicago Electric 96698 operating instructions Troubleshooting, Problem Possible Causes Likely Solutions