Installation Instructions

CMA351

Installation

IMPORTANT ! : The following installation procedure assumes that a 1 ½" NPT pipe has been properly installed to the ceiling.

1.Place one Nylon washer (C) over each stud on Swivel Adapter (A). (See Figure 1)

2.Align slots in stop plate (B) with two threaded studs on Swivel Adapter (A). (See Figure 1)

3.Secure Stop plate (B) to Swivel Adapter (A) using two lock nuts (D). (See Figure 1)

NOTE: DO NOT fully tighten lock nuts at this time.

(B) X1

2

 

(C) X2

1

(A) X1

 

(D) X2

 

 

3

(A) X1

 

Figure 1

4.Thread Swivel Adapter (A) onto existing 1 ½" NPT pipe. (See Figure 2)

5.Secure Swivel Adapter (A) to 1 ½" NPT pipe using one Set Screw (F) and hex wrench. (See Figure 2)

(F) X1

4

5

(A) X1

Figure 2

6.Rotate the bottom of Swivel Adapter (A) until middle set screw in swivel adapter (A) makes contact with tab in stop plate (B). (See Figure 3)

NOTE: This is considered the first stop position.

 

Tab

 

(Not Visible)

6

Lower Set

 

Screw

 

(B) X1

 

(A) X1

 

Tab

 

Lower Set

 

Screw

 

TOP VIEW

Figure 3