Chromalox®
Installation, Operation
and
MAINTENANCE INSTRUCTIONS
SERVICE REFERENCE
DIVISION 4 |
| SECTION NWHMT | |
SALES | (Supersedes | ||
REFERENCE |
DATE APRIL, 1999
Type NWHMT Circulation Heater
(for Water Heating)
Internal
Thermostat
1” Pipe
Outlet (Std.)
2 Mtg. Lugs ea. with two 3/8” - 16 x
1” Pipe
Inlet (Std.)
|
| |
3” |
|
|
C | B | A |
| 3” |
|
Specifications — Table A
Model | Volts | Phase | kW | W/In2 | Dimensions (In.) | |||
A | B | C | ||||||
|
|
|
|
| ||||
120, 240 or 480 | 1 or 3 | 3 | 50 | — | ||||
|
|
|
|
|
|
|
| |
240 or 480 | 1 or 3 | 4.5 | 50 | — | ||||
|
|
|
|
|
|
|
| |
240 or 480 | 1 or 3 | 6 | 50 | |||||
|
|
|
|
|
|
|
| |
240 or 480 | 1 or 3 | 9 | 50 | |||||
|
|
|
|
|
|
|
| |
240 or 480 | 1 or 3 | 12 | 50 | |||||
|
|
|
|
|
|
|
| |
240 or 480 | 1 or 3 | 15 | 50 | |||||
|
|
|
|
|
|
|
| |
240 or 480 | 1 or 3 | 18 | 50 |
3/8” NPT | 7” |
Pipe Plug |
GENERAL
WARNING: This heater is not intended for use in haz- ardous atmospheres where flammable vapors, gases, liquids or other combustible atmospheres are present as defined in the National Electrical Code. Failure to comply can result in explosion or fire.
Hazardous area terminal housings are available, consult your Local Chromalox representative for details.
The NWHMT series is a
The three Copper sheathed tubular elements are centered in a 2- 1/2” diameter galvanized heating chamber and sealed in a removable screwplug. The assembly is surrounded by
metal jacket.
Depending upon the specifications, the NWHMT may or may not be factory equipped with AR or other Chromalox thermostats. Such thermostats function to control outlet temperatures and limits internal temperatures under abnormal flow conditions. These controls do not
CAUTION: Users should install adequate
INSTALLATION
WARNING: Hazard of Shock. Disconnect all power before installing heater.
1.Vertical mounting (axis of chamber vertical, see above drawing.) is preferred with terminal housing at top of heater (Figure 1).
2.When mounting heater horizontally, inlet and outlet pipes must be up. In any other position, heater cannot be purged of air and ele-
ments may be seriously damaged (Figure 2).
3.The NWHMT series of circulation heaters are provided with mounting lugs to support the heater chamber. Refer to drawing above for location of these mounting lugs.
4.Mount heaters to permit unrestrained expansion of chamber due to temperature. This can be accomplished by using a slotted mount- ing assembly on either of the lugs.
Correct
Incorrect |
Correct Incorrect
Figure 1 — Vertical Mounting
Figure 2 — Horizontal Mounting