Chromalox®
Installation, Operation
and
RENEWAL PARTS IDENTIFICATION
DIVISION 4 |
| SECTION GCH | |
SALES | (Supersedes |
| |
REFERENCE | |||
|
|
|
|
DATE FEBRUARY, 1999
Type GCH/GCHIS Circulation Heater (for Steam, Gas and Air Heating)
3/4" NPT Pipe Plug
| Outlet |
|
| 2 Mtg. | Mounting |
| Lugs | |
| Lugs Ea. - Min. |
|
|
| OR |
| Inlet |
|
| K.O. for Conduit |
|
Temperature | Terminal |
|
Housing |
| |
Control |
| Terminal |
(when | Housing | |
specified) | ||
|
Outlet
Temperature
Control
(when
specified)
Inlet
K.O. for Conduit
Specifications – Design is dependent upon size of heater and customer's specifications.
GENERAL
WARNING: Safe operating conditions depend on oper- ating pressure, mass velocity of gas and discharge temperature of the gas. At a given discharge gas tem- perature, heater element sheath temperature and pipe body temperature will increase as gas flow (mass velocity) decreases. The standard GCH has a 750˚F limitation on the carbon steel body and 1500˚F limit on the INCOLOY® sheath elements. Pressure limits vary as the temperature of the vessel increases. If the vessel temperatures exceed 250˚F or operating pres- sure is greater than 100psi, the vessel limits must be evaluated at the specific pressures and temperatures expected during operation. Contact Chromalox if any doubt exists as to temperatures that will be encoun- tered in your specific application. At pipe body tem- peratures above 750˚F, a stainless steel body is required (Model GCHIS).
WARNING: Do not exceed the
WARNING: This heater is not intended for use in haz- ardous atmospheres where flammable vapors, gases, liquids or other combustible atmospheres are present as defined in the National Electrical Code. Failure to comply can result in explosion or fire.
The GCH/GCHIS series is a general purpose gas or steam circu- lation heater intended for indoor use. This heater can be used in an outdoor environment, if ordered with an E4
The INCOLOY® sheathed tubular elements are centered in a steel/stainless steel heating chamber and welded to a removable steel/stainless steel flange. The number of elements will vary, depending upon the flange size used. Some units are fitted with baf- fles to increase the flow. They are designated as GCHB. The assem- bly is surrounded by insulation and a sheet metal jacket.
Depending upon the order specifications, the GCH/GCHIS may or may not be factory equipped with an AR or other Chromalox ther- mostat. Such thermostats function to control outlet temperatures and to limit internal temperatures under abnormal flow conditions. These controls are not
WARNING: Users should install adequate
© 2010 Chromalox, Inc.