Chromalox PE433-3 installation instructions General, Installation, Date November, Chromalox

Models: PE433-3

1 2
Download 2 pages 46.36 Kb
Page 1
Image 1
Chromalox®

Chromalox®

Installation Instructions

and

RENEWAL PARTS IDENTIFICATION

3-1/4”

 

 

3/4 - 14 NPT Outlet

 

 

(Int. Thread)

 

 

 

SERVICE REFERENCE

DIVISION 4

 

SECTION GCHIS-C

SALES

(Supersedes PE433-2)

PE433-3

REFERENCE

161-562803-001

DATE NOVEMBER, 1998

1”

GCHIS-C Circulation Heater

 

 

 

 

 

 

 

 

 

 

 

 

3”

 

For Gas Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) 3/8 - 16

 

 

 

 

 

 

 

 

 

 

Mounting Lugs

Specifications — Table A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type “J”

 

Model

 

 

 

 

Dimensions (In.)

Thermocouple

B

 

 

 

 

 

 

 

 

 

Ungrounded

E1

E2

kW

Volts

CKT

PH

A

B

C

Junction

 

C

A

GCHIS-CO5

GCHIS-CO5E2

0.5

120

1

1

14

8

4

 

 

 

GCHIS-CO5

GCHIS-CO5E2

0.5

240

1

1

14

8

4

 

 

GCHIS-C10

GCHIS-C10E2

1.0

120

1

1

20

14

10

1” Thick

 

GCHIS-C10

GCHIS-C10E2

1.0

240

1

1

20

14

10

 

GCHIS-C20

GCHIS-C20E2

2.0

120

1

1

32

26

22

Insulation

 

 

 

GCHIS-C20

GCHIS-C20E2

2.0

240

1

1

32

26

22

 

 

GCHIS-C30

GCHIS-C30E2

3.0

240

1

1

44

38

34

 

3/4 - 14 NPT

 

 

 

 

 

 

 

 

 

 

Inlet

 

 

 

 

 

 

 

 

 

 

* (2) 1/2” Conduit

 

 

 

 

 

 

 

 

 

 

Openings 90˚ Apart

 

 

 

 

 

 

 

 

 

 

* (2) 1” NPT

 

 

 

 

 

 

 

 

 

4”

Hubs

3-1/2”

 

 

 

 

 

 

 

 

* Power and “K” Over temperature

 

 

 

 

 

 

 

 

 

Thermocouple Connections (Not Shown)

 

 

 

 

 

 

 

 

 

E1 General Purpose Enclosure

E2 Moisture-Resistant/Explosion-Resistant Enclosure

GENERAL

WARNING: This heater is not intended for use in haz- ardous atmospheres where flammable vapors, gases, liquids or other combustible atmospheres are pre- sent as defined in the National Electrical Code. Failure to comply can result in explosion or fire.

The GCHIS-C is a gas circulation heater, designed especially for low flow rates and/or high temperature applications.

The INCOLOY® sheathed cartridge style heating element is cen- tered in a 304 stainless steel pipe body. High temperature insulation and jacket envelope the pipe body to reduce heat loss. Its screwplug type mounting provides easy removal when necessary.

A Type K thermocouple is located inside the heating element sheath to provide overtemperature protection. Accurate process control can be achieved by means of the Type J thermocouple installed in the heater outlet. (Process and Hi-limit Controllers ordered separately.)

WARNING: Users should install adequate back-up con- trols and safety devices with their electric heating equipment. When heating in closed vessels where the consequences of failure may be severe, controls and back-up controls must be used to prevent buildup of temperature and/or pressure. Although the safety of the installation is the responsibility of the user, Chromalox will be glad to make equipment recommendations.

INSTALLATION

WARNING: Hazard of Electric Shock. Disconnect all power

 

mounting lugs to support the heater chamber. Refer to figure for

before installing heater.

 

location of these mounting lugs.

1.

Before installing, check your GCHIS-C circulation heater for any

6. Mount heaters to permit unrestrained expansion of chamber due

 

to temperature. This can be accomplished by using slotted mount-

 

damage that may have occurred during shipment.

 

2.

 

ing assembly on either of the lugs.

Check to insure that the line voltage is the same as that stamped on

 

7. Provide adequate space at terminal end to permit withdrawal of

 

the nameplate.

3.

 

the heater from chamber should servicing be required.

Vertical mounting (axis of chamber vertical as in figure above)

 

8.

DANGER: Hazard of Fire. Provide a minimum of 6” spacing

 

is preferred.

4.

 

from chamber and related piping to nearest combustible material.

To avoid excess temperatures at electrical wiring, mount heater

 

 

Do not operate heater near combustible fluids or in combustible

 

with terminal enclosure at bottom, and use lower nozzle as inlet

 

 

 

vapor or gas laden atmosphere.

 

to the circulating steam, air or gas.

 

5.

9. If two or more heaters are required to provide the needed heating

The GCHIS-C series of circulation heaters is provided with

 

capacity, arrange them for series gas or vapor flow.

 

 

 

© 2010 Chromalox, Inc.

Page 1
Image 1
Chromalox PE433-3 installation instructions General, Date November, Chromalox, Installation Instructions