Chromalox PF497-1 specifications General, Chromalox, Installation, Operation, 161-304812-001

Models: PF497-1

1 6
Download 6 pages 34.74 Kb
Page 1
Image 1
Chromalox®

Chromalox®

Installation, Operation

and

RENEWAL PARTS IDENTIFICATION

 

 

 

 

DIVISION 4

 

SECTION DRA

SALES

(Supersedes(S des PG422PF-497)-1)

PF497-1

REFERENCE

 

 

 

161-304812-001
DATE NOVEMBER, 2002

 

Portable Industrial

Unit Blower Air Heater

Type DRA

Specifications – Table 1

Model

 

Electrical Data (60 Hz)

 

 

Dimensions (In.)

 

Volts

kW

Phase

Amps* 1/3 Ph

BTU

Height

Width

Depth

 

DRA-07-83

208

7.5

1 and 3

36.3/21.0

25,590

34.25

27.5

25

DRA-07-23

240/208

7.5/5.6

1 and 3

31.5/18.3**

25,590

34.25

27.5

25

DRA-10-83

208

9.75

1 and 3

47.1/27.3

33,267

34.25

27.5

25

DRA-10-23

240/208

9.75/7.3

1 and 3

40.8/23.7**

33,267

34.25

27.5

25

DRA-15-83

208

15

3

41.8

51,180

34.25

27.5

25

DRA-15-23

240/208

15/11.2

3

36.3**

51,180

34.25

27.5

25

DRA-15-43

480

15

1 and 3

31.4/18.2

51,180

34.25

27.5

25

DRA-15-63

600

15

1 and 3

25.2/14.6

51,180

34.25

27.5

25

DRA-20-23

240/208

19.5/15

3

47.1**

66,534

34.25

27.5

26.5

DRA-20-43

480

20

1 and 3

42.0/24.4

68,240

34.25

27.5

26.5

DRA-20-63

600

20

1 and 3

33.5/19.4

68,240

34.25

27.5

26.5

DRA-30-43

480

30

3

36.3

102,360

34.25

27.5

26.5

DRA-30-63

600

30

3

20.1

102,360

34.25

27.5

26.5

 

 

 

 

 

 

 

 

 

*= Includes motor amps

**= Ratings shown are for 240V, 208V amperage is 86% of 240V value.

Models shown as 1 and 3 phase are factory wired for 3 phase operation and can be field wired for single phase.

GENERAL

IMPORTANT:

SAVE THESE INSTRUCTIONS

Risk of fire. Do not use as a residential or house- hold heater.

Hazard of Fire or Discoloration of Temperature Sensitive Fabrics. Do not use as a residential or household heater. Keep combustible material and

such fabrics away from heater. Do not operate heater where flammable vapors, gases or liquids are present. Heaters in the heat mode should not be operated in room temperatures above 80°F. Fan motor is not designed to operate in ambients below -40°F.

To avoid personal injury read “IMPORTANT INSTRUCTIONS” on page 2 before installation or operation of heater.

Keep electrical cords and combustible materials, such as drapes and other furnishings, away from heater.

© 2010 Chromalox, Inc.

Page 1
Image 1
Chromalox PF497-1 specifications General, Risk of fire. Do not use as a residential or house- hold heater, Chromalox