Chromalox PG442 specifications General, Installation, Save These Instructions

Models: PG442

1 4
Download 4 pages 63.59 Kb
Page 2
Image 2
GENERAL

GENERAL

IMPORTANT:

SAVE THESE INSTRUCTIONS

FIRE HAZARD. Do not use as a residential or household heater. Keep combustible material away from heater. Do not operate heater where flamma- ble vapors, gases or liquids are present.

To avoid personal injury read “IMPORTANT INSTRUCTIONS” on this page before installation or operation of heater.

INSTALLATION

The Chromalox RBC-1 radiant heater is shipped fully assem- bled. The heater can be hung from the ceiling by chains or rigid angle brackets attached to the heater brackets located on the back of the heater. (Chromalox offers hanging chain kits for these heaters that will allow for installations to 6 feet from the ceiling.) Minimum spacings:

Ceiling to top of heater is 3 in. Wall to sides of heater is 12 in. Floor to bottom of heater is 10 feet.

Installer should consult state and local codes and meet any applicable requirements regarding the installation.

 

 

("A")

 

 

 

("B")

 

 

 

VIEW SHOWN WITH

 

 

 

COVER REMOVED

 

Ø1.125

 

 

 

SERVICE

 

4X1/4" Ø MOUNTING

 

ENTRANCE

 

 

 

HOLE FOR "S" HOOKS

 

OPENING

 

 

 

 

 

 

 

(3.500)

(4.500)

 

1.000±.062

(8.375)

 

 

90˚

 

 

 

 

(10.000)

 

Ø.475

 

 

 

 

Figure 2

Min.

Min.

Min.

Min.

Figure 3