Type HB Heater Bands
for Barrel or Surface Temperatures up to 800˚F
Specifications — Table A
|
|
|
|
|
|
|
|
| Model | PCN | Volts | Watts | W/In2 | Amperes | Barrel Diameter | Wt |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (In.) | (Lbs.) |
|
|
|
|
|
|
|
|
| 273631 | 240 | 750 | 50 | 3.1 | 5 | 1.5 | |
|
|
|
|
|
|
|
|
| 273287 | 240 | 800 | 48 | 3.3 | 1.75 | ||
|
|
|
|
|
|
|
|
| 272760 | 240 | 600 | 33 | 2.5 | 1.75 | ||
|
|
|
|
|
|
|
|
| 273463 | 240 | 1500 | 82 | 6.3 | 1.75 | ||
|
|
|
|
|
|
|
|
| 269149 | 240 | 400 | 20 | 1.7 | 6 | 2 | |
|
|
|
|
|
|
|
|
| 268998 | 240 | 750 | 38 | 3.1 | 6 | 2 | |
|
|
|
|
|
|
|
|
| 269464 | 240 | 1000 | 48 | 4.2 | 2 | ||
|
|
|
|
|
|
|
|
| 273623 | 240 | 1000 | 43 | 4.2 | 7 | 2 | |
|
|
|
|
|
|
|
|
| 273586 | 240 | 1500 | 53 | 6.3 | 2.25 | ||
|
|
|
|
|
|
|
|
| 273578 | 240 | 1250 | 48 | 5.2 | 2.25 | ||
|
|
|
|
|
|
|
|
| 269157 | 240 | 900 | 35 | 3.8 | 2.25 | ||
|
|
|
|
|
|
|
| 1/4” spacing between | 269000 | 240 | 900 | 30 | 3.8 | 8 | 2 | |
|
|
|
|
|
|
|
| 273599 | 240 | 1400 | 50 | 5.8 | 8 | 2.25 | ||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
| multiples. | 269886 | 240 | 1565 | 53 | 6.5 | 2.3 | ||
|
|
|
|
|
|
|
|
| 269018 | 240 | 1100 | 33 | 4.6 | 9 | 2.5 | |
|
|
|
|
|
|
|
|
| 272073 | 240 | 1710 | 53 | 7.1 | 2.5 | ||
|
|
|
|
|
|
|
|
| 269165 | 240 | 1300 | 35 | 5.4 | 2.75 | ||
|
|
| 273640 | 240 | 1600 | 45 | 6.7 | 2.75 | ||||||||
| Type HB | |||||||||||||||
|
|
|
|
|
|
|
|
| 269878 | 240 | 1800 | 48 | 7.5 | 10 | 3 | |
|
|
|
|
|
|
|
|
| 273615 | 240 | 2600 | 68 | 10.8 | 3 | ||
|
|
|
|
|
|
|
|
| 269026 | 240 | 1200 | 30 | 5.0 | 3 | ||
|
|
|
|
|
|
|
|
| 272305 | 240 | 2025 | 48 | 8.4 | 11 | 3.25 | |
|
|
|
|
|
|
|
|
| 260034 | 240 | 1200 | 28 | 5.0 | 3.25 | ||
|
|
|
|
|
|
|
|
| 273711 | 240 | 1700 | 38 | 7.1 | 3.25 | ||
|
|
|
|
|
|
|
|
| 269042 | 240 | 1500 | 30 | 6.3 | 3.5 | ||
|
|
|
|
|
|
|
|
| 269050 | 240 | 1800 | 38 | 7.5 | 3.75 | ||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| 269130 | 240 | 1200 | 23 | 5.0 | 14 | 3.9 | |
|
|
|
|
|
|
|
|
| ||||||||
269069 | 240 | 2500 | 45 | 10.4 | 14 | 3.9 | ||||||||||
|
|
|
|
|
|
|
|
| 269077 | 240 | 2500 | 40 | 10.4 | 4 | ||
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| 263986 | 240 | 2500 | 38 | 10.4 | 17 | 4.2 | |
|
|
|
|
|
|
|
|
| 263994 | 240 | 2500 | 38 | 10.4 | 4.3 | ||
|
|
|
|
|
|
|
|
| 264006 | 240 | 2500 | 38 | 12.5 | 20 | 4.5 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GENERAL
WARNING: This heater is not intended for use in | 2. | WARNING: Hazard of heater failure. Pipe or barrel |
hazardous atmospheres where flammable vapors, |
| surface temperature not to exceed 800˚F. |
gases, liquids, or other combustible atmospheres | 3. | Heater bands may be used individually or in multiples spaced |
are present as defined in the National Electrical |
| 1/4” apart. |
Code. Failure to comply can result in explosion or | 4. | WARNING: Users should install adequate controls |
fire. |
| and safety devices with their electric heating |
|
| equipment. Where consequences of failure may be |
1. Heater Construction Characteristics — | severe, | |
the safety of the installation is the responsibility of | ||
B. Two (2) | ||
the user, Chromalox will be glad to make equip- | ||
ments. | ||
ment recommendations. | ||
C.Heavy construction of clamp and | ||
| ||
bolt allow firm grip on heaters and tight heater fit to pipe |
| |
or barrel configuration. |
|
© 2010 Chromalox, Inc.