Chromalox UB-3002A, UB-2502A specifications Mounting, Wiring Diagrams

Models: UB-2502A UB-3002A

1 8
Download 8 pages 28.79 Kb
Page 2
Image 2

MOUNTING

WARNING: Hazard of Electric Shock. Disconnect all power before installing heater.

WARNING: These heaters are designed for wall or ceiling mounting only. Other modes of mounting voids factory warranty.

1.Height above floor

A.In areas where ceiling height is more than 12 feet, recom- mended mounting height is approximately 10 feet to under- side of heater.

B.For ceiling heights of 12 feet or less, maximum mounting height is determined by use of ceiling mounting brackets

offered with these heaters. Minimum spacing to ceiling is 14-1/4”.

C.In either case, the minimum mounting height is 7 feet from floor to bottom of heater. (See Figures 1 and 2.)

2.Spacing to adjacent walls

A.Rear of case to back wall 11” minimum.

B.Side of case to side wall 12” minimum.

3.If two or more units are operated in the same enclosed space, their discharges should be directed to aid in development of mass air movement for uniform heat dispersal.

4.Controlling thermostats to individual heaters should be mount- ed at shoulder height on inside walls or columns.

WIRING

Note: All wiring should be done in accordance with local codes and the National Electrical Code by a qualified person.

WARNING: Hazard of Electric Shock. Any installa- tion involving electric heaters must be effectively grounded in accordance with the National Electrical Code to eliminate shock hazard.

1.Connect heater according to the voltage and frequency speci- fied on the nameplate and using the appropriate wiring diagram (Figures 3 thru 11).

Note: Be sure to check the voltage rating of the fan motor since it is not necessarily the same as the heater circuit.

2.If an external transformer is used to step down the voltage for operating the fan motor, use appropriate wiring diagram (Figures 8 thru 11).

3.Heaters are not provided with a control switch and should be controlled by externally mounted disconnect switches and/or separately mounted thermostat and control switch as recom- mended in appropriate wiring diagrams (Figures 3 thru 11). Key to proper wiring diagram is the part number (P/N) of inter- nal wiring diagram located on inside of the hinged cover of the terminal box.

4.Protection against overheating is provided by an internal auto- matic thermal cutout which opens the electric circuit if the nor- mal air-flow is restricted or stopped. Cutout automatically energizes heater on removal of the obstruction.

WIRING DIAGRAMS

Figure 3

2

Page 2
Image 2
Chromalox UB-3002A, UB-2502A specifications Mounting, Wiring Diagrams

UB-2502A, UB-3002A specifications

Chromalox has established itself as a leader in electric thermal technologies, providing innovative solutions for industrial heating applications. Among its extensive product range, the UB-3002A and UB-2502A models stand out for their reliability and performance. These industrial electric heaters are designed to meet diverse process heating needs in various applications, including comfort heating, freeze protection, and process temperature maintenance.

The UB-3002A is a powerful unit featuring a robust design that facilitates efficient heating in a range of settings. With a wattage output of 3000 watts, it is ideal for situations requiring substantial heat transfer. This model is equipped with a finely calibrated temperature control system that ensures consistent operation within specified temperature ranges. The UB-2502A, while slightly less powerful with a wattage output of 2500 watts, offers equally impressive features suitable for less intensive applications but still requiring reliable performance.

Both models benefit from advanced thermal technology, which integrates highly efficient heating elements that provide optimal energy utilization. This efficiency helps to reduce operational costs and improves the sustainability of heating systems. Furthermore, these units are designed with safety in mind, featuring built-in overheating protection mechanisms and durable materials that withstand harsh industrial environments.

In terms of installation and maintenance, the Chromalox UB series supports easy integration into existing systems. The robust construction materials not only enhance durability but also minimize the need for frequent maintenance, making these models practical for many industrial setups. Their compact design allows them to fit into tight spaces, giving users more flexibility in application.

Moreover, both models feature versatile mounting options, making them suitable for wall-mounted or ceiling-mounted installations depending on the specific heating requirements of the environment. The compatibility of the UB-3002A and UB-2502A with various environmental conditions showcases their adaptability.

In summary, the Chromalox UB-3002A and UB-2502A electric heaters deliver high-performance heating solutions tailored for industrial environments. With their proven technology, energy efficiency, and robust safety features, these models exemplify reliability in thermal management systems. Businesses looking for effective and adaptable heating solutions will find the UB series to be an invaluable addition to their operational capabilities.