Safety Precautions
Safety Precautions
Observe the following safety precautions when you are installing a LightStream 2020 multiservice ATM switch.
Warning and Caution
Warning LS2020 switches are designed and manufactured to meet accepted safety standards. However, improper use can result in electrical shock, fire hazards, and personal injury. Read the following instructions carefully before installing and using an LS2020 switch. Heed all Cautions and Warnings.
Electrostatic Discharge Protection
Static electricity can damage or degrade electronic components. Therefore, observe the precautions described below in handling LS2020 hardware.
Grounding Procedure
Before removing any part of the LS2020 enclosure to expose its circuitry, you must ensure that you, the equipment rack, and the circuit boards are at ground potential to prevent electrostatic discharge (ESD). Such spurious discharges can damage LS2020 components. To place yourself at ground potential, wear a wrist strap connected to one of the ESD grounding jacks on the front and rear of the LS2020 chassis or to the bare metal chassis frame itself.
Card Protection
All spare cards are shipped in separate, reusable antistatic shielding bags. Store each card in its bag until the card is installed in the machine. Do not remove a card from its bag unless you are grounded. Do not place a bag on exposed electrical contacts where it can cause short circuits.
Glossary of TCS Hub Commands
The following test and control system (TCS) hub commands are used in this manual:
•
•
•
•
•
reset <slot#>
connect <slot#>
show <sa sb>
set <sa sb>
init <sa sb> modem
Resets the card in the specified slot
Establishes a connection to the card in the specified slot
Detects the baud rate for the specified switch
Sets the baud rate for the specified switch
Initializes the modem port on the specified switch
xivLightStream 2020 Installation Guide