QuickSpecs

Cisco MDS 9216A Multilayer Fabric Switch

Technical Specifications

IEC60825

EN60825

21 CFR 1040

EMC compliance

 

FCC Part 15 (CFR 47) Class A

 

ICES-003 Class A

 

EN 55022 Class A

 

CISPR 22 Class A

 

AS/NZS 3548 Class A

 

VCCI Class A

 

 

EN 55024

 

 

EN 50082-1

 

 

EN 61000-6-1

 

EN 61000-3-2

 

EN 61000-3-3

Power and Cooling

Power supply (845W AC)

 

AC input characteristics

 

100 to 240 VAC (10% range)

 

50-60Hz (nominal)

 

Airflow

 

 

200 linear feet per minute (lfm) through system fan assembly.

 

Cisco recommends that you maintain a minimum air space of 6 inches (16 cm) between

 

walls and the chassis air vents and a minimum separation of 12 inches (30.5 cm) between

 

two chassis to prevent overheating.

Environmental

Temperature, ambient

32° to 104° F (0° to 40° C)

 

operating

 

 

Temperature, ambient

40°F to 158° F (-40°C to 75° C)

 

non-operating and storage

 

Relative humidity, ambient 10 to 90% (non-condensing)

operating

Relative humidity, ambient 10 to 95% (non-condensing) non-

operating and storage

 

Altitude, operating

-197 to 6500 feet (-60 to

2000 meter)

Dimensions (HxWxD)

5.25 x 17.32 x 22.66 in (13.34 x 43.99 x 57.56 cm)

 

3 Rack Units (RU)

 

 

 

All units rack mountable in standard 19 inch EIA rack

 

 

 

 

 

© Copyright 2008 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

DA - 12122 Canada — Version 8 — February 22, 2008

Page 15

Page 15
Image 15
Cisco Systems MDS 9216A manual Power and Cooling, Environmental, Dimensions HxWxD