6
Technical remarks
Internal connections of the electrical heating
▲ | Heating |
|
| 3x220V | R5 | 3x380V | R5 |
| ||
|
|
|
|
|
|
|
|
|
| |
|
| 9kw | 3x3kw |
| ▲ | LC1D1810 | ★ | LC1D0901 |
| |
|
|
|
|
|
|
|
|
|
| |
| 12kw | 3x2kw |
| ▲ | LC1D253 | ★ | LC1D0901 |
| ||
|
|
| 3x2kw |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 15kw | 3x2kw |
| ▲ | LC1D253 | ★ | LC1D1810 |
| ||
|
|
| 3x3kw |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 18kw | 3x3kw |
| ▲ | LC1D323 | ★ | LC1D1810 |
| ||
★ |
|
| 3x3kw |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
21kw | 3x3kw |
| ★ | LC1D1810 |
| |||||
|
|
| ||||||||
|
|
| 3x4kw |
| ▲ | LC1D1810 |
| |||
|
|
|
|
|
|
|
|
| ||
| 24kw | 3x4kw |
| ▲ | LC1D1810 |
| ||||
|
|
| 3x4kw |
| ▲ | LC1D1810 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| B = Black |
|
|
|
|
|
|
Gy = Grey
R = Red
PU = Purple
Br = Brown
Bu = Blue
W = White
W/B = White/black
Tilt switch
1/2 | 1/2 |
Window
1/3 | Probe |
|
Remark:
Other executions are available as options
The tilt switch is mounted on the solid part of the machine. There is a window around the probe of the tilt switch that is mounted on the movable part of the machine.
When the machine goes out of balance by overloading or uneven distribution of the linen, the tilt switch will interrupt this action to prevent damage to the machine.
Important
To guarantee good functioning, the probe should be centered horizontally and vertically at 1/3 from the bottom of the tilt window (when machine drum is empty)