6

Technical remarks

Internal connections of the electrical heating

Heating

 

 

3x220V

R5

3x380V

R5

 

 

 

 

 

 

 

 

 

 

 

 

 

9kw

3x3kw

 

LC1D1810

LC1D0901

 

 

 

 

 

 

 

 

 

 

 

 

12kw

3x2kw

 

LC1D253

LC1D0901

 

 

 

 

3x2kw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15kw

3x2kw

 

LC1D253

LC1D1810

 

 

 

 

3x3kw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18kw

3x3kw

 

LC1D323

LC1D1810

 

 

 

3x3kw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21kw

3x3kw

 

------

------

LC1D1810

 

 

 

 

 

 

 

3x4kw

 

------

------

LC1D1810

 

 

 

 

 

 

 

 

 

 

 

24kw

3x4kw

 

------

------

LC1D1810

 

 

 

 

3x4kw

 

------

------

LC1D1810

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B = Black

 

 

 

 

 

 

Gy = Grey

R = Red

PU = Purple

Br = Brown

Bu = Blue

W = White

W/B = White/black

Tilt switch

1/2

1/2

Window

1/3

Probe

 

Remark:

Other executions are available as options

The tilt switch is mounted on the solid part of the machine. There is a window around the probe of the tilt switch that is mounted on the movable part of the machine.

When the machine goes out of balance by overloading or uneven distribution of the linen, the tilt switch will interrupt this action to prevent damage to the machine.

Important

To guarantee good functioning, the probe should be centered horizontally and vertically at 1/3 from the bottom of the tilt window (when machine drum is empty)