Gas Piping

GAS PIPING

 

Check gas rating plate for type of gas to equip the dryer.

INSTALLATION

 

Check for altitude elevation of the dryer.

 

 

 

 

Check utility for proper installation of gas supply line and gas

 

 

pressure.

 

 

NATURAL GAS ONLY

 

 

Check the gas pressure inlet supply to dryer, 11” W.C. Pressure

 

 

maximum. Check the manifold pressure 3.5” W.C. Pressure (Natural

 

 

Gas).

 

 

LP GAS ONLY

 

 

11” W.C. Pressure

 

 

 

 

 

CAUTION

 

 

Low gas pressure and intermittent gas will cause gas ignition

 

 

problems. This will cause inadequate drying of the clothes

 

 

load.

 

 

 

 

 

IMPORTANT

 

 

The dryer and its individual shutoff valve must be

 

 

disconnected from the gas supply piping system during any

 

 

pressure testing of that system at test pressures in excess of

 

 

1/2 PSIG.

 

 

 

 

 

IMPORTANT

 

 

The dryer must be isolated from the gas supply piping system

 

 

by closing its individual manual shutoff valve during any

 

 

pressure testing of the gas supply piping system at test

 

 

pressures equal to or less than 1/2 PSIG.

 

 

 

 

 

 