| Gas Piping |
GAS PIPING |
| Check gas rating plate for type of gas to equip the dryer. |
INSTALLATION |
| Check for altitude elevation of the dryer. |
|
| |
|
| Check utility for proper installation of gas supply line and gas |
|
| pressure. |
|
| NATURAL GAS ONLY |
|
| Check the gas pressure inlet supply to dryer, 11” W.C. Pressure |
|
| maximum. Check the manifold pressure 3.5” W.C. Pressure (Natural |
|
| Gas). |
|
| LP GAS ONLY |
|
| 11” W.C. Pressure |
|
|
|
|
| CAUTION |
|
| Low gas pressure and intermittent gas will cause gas ignition |
|
| problems. This will cause inadequate drying of the clothes |
|
| load. |
|
|
|
|
| IMPORTANT |
|
| The dryer and its individual shutoff valve must be |
|
| disconnected from the gas supply piping system during any |
|
| pressure testing of that system at test pressures in excess of |
|
| 1/2 PSIG. |
|
|
|
|
| IMPORTANT |
|
| The dryer must be isolated from the gas supply piping system |
|
| by closing its individual manual shutoff valve during any |
|
| pressure testing of the gas supply piping system at test |
|
| pressures equal to or less than 1/2 PSIG. |
|
|
|
|
|
|