Dryer Installation With Multiple Exhaust
For Exhaust Duct less than 14 feet and 2 elbows equivalent and less than 0.3 inches static pressure.
No. of Dryers
Duct Diameter (in inches)
(in CM)
No. of Dryers
Duct Diameter (in inches)
(in CM)
No. of Dryers
Duct Diameter (in inches)
(in CM)
DRYER EXHAUSTS
Area of section
MODELS: L28FD30, L28US30, L36FD30, L36UR30, L36CD36, L44FD42
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
6 | 9 | 11 | 12 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 23 | 24 | 25 | 26 | 26 | 27 | 28 | 28 | 29 | 30 |
15 | 23 | 27 | 30 | 35 | 38 | 41 | 43 | 46 | 48 | 51 | 53 | 56 | 58 | 58 | 61 | 63 | 66 | 66 | 68 | 71 | 71 | 73 | 76 |
MODELS: L28CD30, L28UR30, L36CD30, L36UR30, L36CD36, L44FD42
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
8 | 12 | 14 | 16 | 18 | 20 | 22 | 23 | 24 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 |
20 | 30 | 35 | 41 | 46 | 51 | 56 | 58 | 61 | 66 | 68 | 71 | 73 | 76 | 78 | 81 | 84 | 86 | 89 | 91 | 94 | 97 | 99 100 |
MODELS: L44CD42, L50CD42
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
12 | 17 | 21 | 24 | 27 | 30 | 32 | 34 | 36 | 38 | 40 | 42 |
30 | 43 | 53 | 61 | 68 | 76 | 81 | 86 | 91 | 97 | 100 106 |
AUTOMATIC ELECTRICAL CONTROL FOR EXHAUST FAN
For one or more dryers to start fan.
Exhaust
Booster Fan
Power Supply
to Fan
Relay Coils
Start and Stop
Switches on
Dryers
_ _ _ _ | _ _ _ _ | _ _ _ _ | _ _ _ _ | _ _ _ _ | _ _ _ _ |
Page 23