Dryer Installation With Separate Exhaust (Preferred)
DRYERINSTALLATION WITHSEPARATEEXHAUST (PREFERRED)
For ductwork less than 14 feet and 2 elbows equivalent and less than 0.3 inches static pressure:
NEVER exhaust the dryer into a chimney.
NEVER install wire mesh screen over the exhaust or
NEVER exhaust into a wall, ceiling, or concealed space.
1.
2.Enclosure (plenum) with service door. This separates the dryer air from the room comfort air. If dryers use room air instead of outside air, additional heat loss can be another 25 BTU/HR (6.3 kcal/hr) for each cubic foot per minute (CFM) (.03m³/min.) used.
3.Zero inches (mm) clearance to combustible material allowed on sides and at points within 4 inches (100 mm) of front on top.
4.Heat loss into laundry room from dryer front panels is about 60 BTU/ HR per square foot (15 kcal/hr per 0.1m²).