Power

Before you start, make sure the source unit’s power switch is off.

WARNING!

To prevent short circuits during installation, disconnect the vehicle’s negative (-) battery lead before making any power connections.

Fuses

To protect the vehicle from fire or explosion in the event of a collision, add an external fuse to the amp’s positive (+) power lead and connect it as close as possible to the vehicle’s plus (+) battery terminal.

Use a fuse rated to the total current consumption of the amplifier. Fuses mounted near the battery should be ~10 Amps bigger than fuses on the amplifier itself.

If you are using more than one amplifier, add the total current consumption for the entire system and use the closest available fuse. For example, if you’re connecting both an APX2180 and an APX4360, install a 100 Amp fuse at the battery.

Power wire size can greatly affect the performance of your audio system. The Power wire size table indicates the minimum power wire requirements for proper operation.

Power wire size table

<12 feet total electrical path length

12-22 feet total electrical path length

Wire size

Maximum fuse

Wire size

Maximum fuse

 

 

 

 

8 Awg

70 Amp

8 Awg

40 Amp

4 Awg

170 Amp

4 Awg

50 amp

 

 

 

 

2 Awg

240 Amp

2 Awg

140 Amp

0 Awg

400 Amp

0 Awg

200 Amp