EN

How To Prepare the Machine For Operation

9.Place the batteries in the compartment shown in Figure 11.

WARNING: The batteries are heavy. Lifting batteries without help could result in an injury. Get help to lift the batter- ies.

WARNING: Working with batteries can be dangerous. Always wear eye protection and protective clothing when working near batteries. NO SMOKING!

10.Connect the cable between the batteries and install the long machine cables as indicated (See Figure 11).

11.Secure the batteries in place with the battery straps (See Figure 12).

12.Reinstall the recovery tank making sure the pivot pin in the recovery tank is installed under the metal plate on the solution tank (See figure 13A.)

13.Reattach the tether to the recovery tank (See figure 10).

WARNING: The recovery tank can fall off of the machine when opening the tank or operating the machine, if the recovery tank is not properly installed. Make sure that the recovery tank pivot pin is under the metal plate on the solution tank and the tether is attached to the recovery tank.

14.Reconnect the vacuum and squeegee hoses to the recovery lid. Make sure the hose to the vacuum motor and the rear squeegee hose are installed over the top of the drain hose (See figure 13B).

15.Reconnect the blue float connector (See figure 9, page 12).

16.Charge the batteries before using the machine.

- +

FRONT

+-

Figure 11

Figure 12

Figure 13A

Figure 13B

Clarke® Operator's Manual -FOCUS S17/L17 and S20/L20