Machine Control Panel
Key Switch (See Figure 3, Item "A") |
| CircuitBreakers(SeeFig3,Items"F","G","H","I"&"J") | |||
The key switch turns "ON" the power to the control |
| The circuit breaker reset buttons are located on the | |||
panel. "O" is "OFF" and "I" is "ON". |
| rear cover. The breakers are located as follows: | |||
Forward Reverse Switch (See Figure 3, Item "B") | Item F - Actuator Head (5 amp) | ||||
Item G - Vacuum Motor (30 amp) | |||||
On Traverse ("L") Model Only - The forward/reverse | Item H& I - Brush Motor (40 amp) | ||||
switch turns the traverse motor "on" forward and if the | Item J - Traverse Motor (25 amp) (L30 only) | ||||
brush motors are in the down position, activates the | If a circuit breaker trips, determine which motor is not | ||||
brush motors/solution control module. There is a two | operating and turn the key switch "OFF". Wait five | ||||
second delay for the pad motor to stop after releasing | minutes and push the reset button back in. Turn the | ||||
the switch. Either the right or the left switch can be | key switch "ON" and try again. An authorized service | ||||
used. Use either switch in conjunction with the white | person should be contacted if the breaker trips again. | ||||
reverse switch to reverse the traverse motor. |
| Control Handles (See Figure 3, Item "K") | |||
"S" Model - These switches activate brush motors |
| ||||
and solution/control module if brush motors are in the | The control handles are located at the rear of the | ||||
down position. |
| machine. They are used to guide the machine. | |||
Battery Meter (See Figure 3, Item "C") |
| Solution Control Knob (See Figure 3, Item "L") | |||
The battery meter indicates the relative charge on the | The solution control knob regulates the flow of chemi- | ||||
battery pack. Do not continue to run the machine |
| cal solution to the floor. To increase the flow, turn | |||
when the needle is in the "red" area. This will shorten | knob clockwise. To decrease the flow, turn counter | ||||
the life of the battery pack. |
| clockwise. Full counter clockwise is OFF and full | |||
Brush Pressure Meter (See Figure 3, Item "D") |
| clockwise is ON. |
|
| |
| Traverse Speed Knob (See Figure 3, Item "M") | ||||
The pad pressure meter indicates the relative amount | |||||
of pressure the pad is putting on the floor. To maxi- | To increase speed, turn knob clockwise. | ||||
mize run time on a battery charge, keep the needle |
| Brush Motor Switch (See Figure 3, Item "N") | |||
towards the center of the green area. |
| ||||
Reverse Switch (See Figure 3, Item "E") |
| To activate brush motor, push brush position switch to | |||
| down position. Brush Motor and solution flow will | ||||
On Traverse Model Only |
| activate when the traverse buttons are pushed. To | |||
The reverse switch, when used in conjunction with one | shut brush motor off, hold brush position switch in up | ||||
of the forward/reverse switches, causes the machine to | position until actuator stops. |
|
| ||
reverse directions. The reverse speed is 70% of the | Vacuum Motor Switch (See Figures 4 & 5, pg. 11) | ||||
forwardspeed. |
| ||||
Hour Meter (Not Illustrated) (Option) |
| To activate vacuum motor, lower squeegee handle. | |||
| Handle has two positions. Lowest position is | ||||
The hour meter indicates the number of hours the |
| operating position and the middle position is transport | |||
machine has operated. It runs only when the brush |
| to clear vacuum hose. |
|
| |
motor is on. |
|
|
|
| |
|
|
| K |
|
|
| E | A | M |
|
|
|
|
|
| ||
| K |
|
| K | |
| B |
| B | ||
|
|
|
|
C
N LD
F G H I J
Figure 3
Page | Clarke® Operator's Manual |