Machine Control Panel

Key Switch (See Figure 3, Item "A")

 

CircuitBreakers(SeeFig3,Items"F","G","H","I"&"J")

The key switch turns "ON" the power to the control

 

The circuit breaker reset buttons are located on the

panel. "O" is "OFF" and "I" is "ON".

 

rear cover. The breakers are located as follows:

Forward Reverse Switch (See Figure 3, Item "B")

Item F - Actuator Head (5 amp)

Item G - Vacuum Motor (30 amp)

On Traverse ("L") Model Only - The forward/reverse

Item H& I - Brush Motor (40 amp)

switch turns the traverse motor "on" forward and if the

Item J - Traverse Motor (25 amp) (L30 only)

brush motors are in the down position, activates the

If a circuit breaker trips, determine which motor is not

brush motors/solution control module. There is a two

operating and turn the key switch "OFF". Wait five

second delay for the pad motor to stop after releasing

minutes and push the reset button back in. Turn the

the switch. Either the right or the left switch can be

key switch "ON" and try again. An authorized service

used. Use either switch in conjunction with the white

person should be contacted if the breaker trips again.

reverse switch to reverse the traverse motor.

 

Control Handles (See Figure 3, Item "K")

"S" Model - These switches activate brush motors

 

and solution/control module if brush motors are in the

The control handles are located at the rear of the

down position.

 

machine. They are used to guide the machine.

Battery Meter (See Figure 3, Item "C")

 

Solution Control Knob (See Figure 3, Item "L")

The battery meter indicates the relative charge on the

The solution control knob regulates the flow of chemi-

battery pack. Do not continue to run the machine

 

cal solution to the floor. To increase the flow, turn

when the needle is in the "red" area. This will shorten

knob clockwise. To decrease the flow, turn counter

the life of the battery pack.

 

clockwise. Full counter clockwise is OFF and full

Brush Pressure Meter (See Figure 3, Item "D")

 

clockwise is ON.

 

 

 

Traverse Speed Knob (See Figure 3, Item "M")

The pad pressure meter indicates the relative amount

of pressure the pad is putting on the floor. To maxi-

To increase speed, turn knob clockwise.

mize run time on a battery charge, keep the needle

 

Brush Motor Switch (See Figure 3, Item "N")

towards the center of the green area.

 

Reverse Switch (See Figure 3, Item "E")

 

To activate brush motor, push brush position switch to

 

down position. Brush Motor and solution flow will

On Traverse Model Only

 

activate when the traverse buttons are pushed. To

The reverse switch, when used in conjunction with one

shut brush motor off, hold brush position switch in up

of the forward/reverse switches, causes the machine to

position until actuator stops.

 

 

reverse directions. The reverse speed is 70% of the

Vacuum Motor Switch (See Figures 4 & 5, pg. 11)

forwardspeed.

 

Hour Meter (Not Illustrated) (Option)

 

To activate vacuum motor, lower squeegee handle.

 

Handle has two positions. Lowest position is

The hour meter indicates the number of hours the

 

operating position and the middle position is transport

machine has operated. It runs only when the brush

 

to clear vacuum hose.

 

 

motor is on.

 

 

 

 

 

 

 