Classe Audio CDP-502 owner manual IR remote control seems not to function

Models: CDP-502

1 48
Download 48 pages 41.3 Kb
Page 44
Image 44

44

5.The screen shows an error message and the Eject button does not eject the disc (or the player shows some other anomalous behavior).

3 Press the Standby button so the screen dims and the blue light goes on.

3 Using the rear panel power switch, turn off the unit for at least thirty seconds. Then turn the power back on and press Standby to restart the unit.

6.The IR remote control seems not to function.

3Ensure that there are no obstacles between the IR remote and the IR sensor (located to the right of the mute button).

3If the batteries are weak, replace them with fresh ones.unit.

7If any units do not appear on the CAN-Bus Devices screen.

3 Select back, then re-select more.

8If the unit remains absent on the CAN-Bus Devices screen or if the select button is disabled when you target the unit.

3 Check that the unit is running the latest software. The target unit may not be CAN-Bus ready and should be updated with the current software from the Classé website http://www.Classeaudio.com/support/service.htm

3 Check the connections. Check that the Category 5 Network Cables are securely connected.

3 If the system involves an SSP-300 or 600, check that you have correctly connected the SSP-300/600 CAN-Bus interface box. The CAN-Bus Interface Box has 3 connections, a pair at one end of the box, a single connector at the other. The single connector should be connected to the SSP CAN OUT. The pair of connectors should be treated as if they are the SSP CAN IN and CAN OUT. It doesn’t matter which you use as CAN IN or CAN OUT. The CAN IN connector on the SSP must be left empty.

3 Check the Can-Bus terminator. If the system involves extended

lengths of CAN-Bus cabling then ensure that the CAN-Bus Terminator is correctly inserted at the end of the daisy chain. If the system involves multiple touchscreen units, try removing the CAN-Bus terminator. It is sometimes not required in these circumstances.

3 Check the cables. Ensure that you are using straight through Category 5 Network Cables.

Page 44
Image 44
Classe Audio CDP-502 IR remote control seems not to function, If any units do not appear on the CAN-Bus Devices screen