•Each compartment has capacity for:
Three, 12˝ x 20˝ x 21⁄2˝ or six, 12˝ x 20˝ x 1˝ deep Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY | less than 20 parts per million |
SILICA | less than 13 parts per million |
pH FACTOR | greater than 7.5 |
CHLORINE | less than 30 parts per million |
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
|
| Right - 3”, Left - 3”, Rear - 3” |
|
| (12” on control side if adjoin- |
|
| ing wall or equipment is over |
|
| 30” high for service acess) |
|
| Contact factory for |
1 1/2” IPS common drain. |
| |
| variances to clearances. | |
Do not connect other units |
| |
|
| |
to this drain. |
|
|
Do not use PVC pipe for |
|
|
|
|
|
|
|
|
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, NSF and CSA.
(NOT TO SCALE) SECT. III PAGE 8 0707