Cleveland
CLASSIC CONVECTION STEAMERS 15 PSI BOILER BASE STYLE
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
Cleveland Classic Series CONVECTION
STEAMERS
TWO COMPARTMENT, PRESSURELESS STEAM COIL GENERATOR
24” WIDE CABINET BASE DESIGN
Cleveland Standard Features
■Cooking Capacity for up to six 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans.
■Pressureless cooking with forced convection steam, permitting doors to be opened while cooking continues.
■Solid State Controls operate water level and safety functions.
■Each compartment is equipped with a 60 minute mechanical timer, separate bypass switch for constant steaming and a cold water condenser for superior cooking results.
■Instant Steam Standby Mode: Holds generator at steaming temperature. Allows unit to start cooking instantly.
■Durable 14 Gauge Stainless Steel Construction: For Compartment Door and Steam Cooking Cavity.
■Separate Main Power Switch for “On/Off”
■Exclusive Steam Cooking Distribution System: The exclu- sive Convection Jets produce a high velocity convection steam without fans. Coved Corner design in cooking compart- ment distributes heat evenly and is easy to keep clean. Creased top & bottom enhance drainage. Cold Water Condenser for each compartment maintains a dry steam. Fully insulated cooking compartment for thermal efficiency. Removable Stainless Steel Slide Racks for easy cleaning.
■Exclusive “Cool to the Touch” Compartment Door Design: Free floating inner door with reversible door gasket provides an air tight seal. Stainless Steel Slam/Latch mechanism pro- vides greater reliability.
■Left Hand Door Hinging: Compartment Doors hinged left, controls on the right.
■Modular Cabinet Base with Hinged Door.
■Steam Coil Generator: Automatic Water Fill on start up. Minimum 35 psi incoming steam pressure required with a
3⁄4˝ steam line.
■Automatic Generator Drain at shutdown: Contains a “Water Jet” Spray Rinse Cleaning Cycle to keep drain clear.
■Automatic Water Level Control System with Low Water Power
■Steam generator equipped with High Limit Pressure Safety Switch, 15 psi Safety Valve, and Steam Generator Pressure Gauge.
■Secondary Low Water
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,
Wash. DC)
■NSF Certified 6˝ Stainless Steel Legs with adjustable flanged feet for a one inch level adjustment.
■Standard Voltage for Controls: 115 volts, 60 Hz, single phase.
■All Controls are serviceable from the front.
MODEL: χ 24-CSM
Short Form Specifications
Shall be Two Compartments, CLEVELAND Convection Steamer, Model 24- CSM, Steam Coil Steam Generator, 115 volts, single phase. Solid State Controls operate timing, water level and safety functions. Steam Generator with Automatic Water Fill on
Options & Accessories | |
❐ Right Hand Door Hinging, Controls on the Left (DHR) | |
❐ | Electronic Timer with Compensating Load Feature (ETC) |
❐ | ON/OFF Steam Switch only for compartment controls (MC) |
❐ | Cafeteria pans in depths of 1˝, 21⁄2˝, 4˝ and 6˝ |
❐ | Additional Power Reducing Valve (PRV) |
❐ | Moisture Separator Trap (MS) |
❐ | Stainless Steel Base Frame (FSS) |
❐ | Compartment Door Steam Shut Off Switch (SCS) |
❐ | Correctional Packages |
❐ | Boiler Descaling Pump Kit (107142) |
❐ | Water Filters |
SECT. III PAGE 5 0707