OPERATING CLEARANCES

Top compartment has capacity for:

Bottom compartment has capacity for:

Three, 12" x 20" x 21⁄2" deep Cafeteria Pans

Six, 12" x 20" x 21⁄2" deep Cafeteria Pans.

or

or

Six, 12" x 20" x 1" deep Cafeteria Pans.

Twelve, 12" x 20" x 1" deep Cafeteria Pans.

or

or

Two, 12" x 20" x 4" deep Cafeteria Pans

Four, 12" x 20" x 4" deep Cafeteria Pans

 

 

25.50"

648mm

2.68"

68mm

38.84"

29.25"987mm 743mm

54.94"

1395mm

92º

90º

OPERATING CLEARANCES

3" Left, 3" Right and 3" Rear.

SERVICE CLEARANCES

12" on control side. Contact factory for variances to clearances.

CONTROLS (per compartment)

60-minute electro mechanical timer with load compensating feature. Three function control switch for Timed Cooking and Continuous Steaming.

APPROVALS

UL - Gas, UL - Sanitation (NSF Standards)

GAS (one connection per unit)

1/2” Dia. IPS

SUPPLY32,000 & PRESSURE32,000 BTU’s: NATURAL - 4.00’ W.C. minimum, 14.00” W.C. maximum PROPANE - 12.00” W.C. minimum, 14.00” W.C. maximum

Manufacturer must be notified if unit will be used above 2,000 ft. altitude.

SERVICE CLEARANCES ELECTRICAL (one connection per unit) 115V, 1 Phase, 35 Watts.

C1 C2 C1COLD WATER

C2: Condensing Water Inlet, 35 Psi Minimum, 60 Psi Maximum. : Fill Water Inlet, 35 Psi Minimum, 60 Psi Maximum.

Two 3/4" NH-F (Garden Thread) connections. Use NSF approved hose.

DDRAIN CONNECTION

1" NPT-M

Do not connect other units to this drain.

Drain line must be vented. Vented drain connection included.

Do not connect drain to PVC pipe.

25.50"

648mm

66.09"

1679mm

38.84"

987mm

43.57"

1107mm

7.73"

196mm

2.68"

68mm

G

61.60"

1565mm

G

C1

25.79"

655mm

C2

20.11"

 

511mm

16.40" D 8.39" 417mm 21.3mm

2.02"

51mm

G

G

C1

C2

D

4.83"

123mm

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsi bility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L/NSF#4 and CSA (AGA, CGA).

(NOTB TO SCALE)16

SECT. PAGE Litho in U0309.S.A.