Cleveland Range 42-CKEM-48 Water Quality Requirement, Electric, Water C, Drainage, Clearance

Models: 42-CKEM-48 42-CKEM-24 42-CKEM-36

1 2
Download 2 pages 57.3 Kb
Page 2
Image 2
WATER QUALITY REQUIREMENT

ACTUAL CAPACITIES:

Kettle 6 gallons/23 liters or 192, 4 oz. servings.

Other size servings may be calculated. Each compartment has capacity for:

Three, 12˝ x 20˝ x 212˝ or six, 12˝ x 20˝ x 1˝ deep Cafeteria Pans.

WATER QUALITY REQUIREMENT

The recommended minimum water quality stan- dards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows:

TOTAL DISSOLVED

 

SOLIDS

less than 60 parts per million

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.

ELECTRIC ELECTRIC

KW

Volts

Watts

Ph

Amps

Wire

24

208

21,500

1

103.4

2

 

 

 

 

 

 

 

220

24,000

1

109.1

2

 

240

24,000

1

100.0

2

 

 

 

 

 

 

 

440

20,200

1

45.9

2

 

480

24,000

1

50.0

2

 

 

 

 

 

 

 

208

21,500

3

59.7

3

 

220

24,000

3

63.1

3

 

 

 

 

 

 

 

240

24,000

3

57.8

3

 

440

20,200

3

26.5

3

 

 

 

 

 

 

 

480

24,000

3

28.9

3

 

600

24,000

3

23.1

3

 

 

 

 

 

 

 

360

21,500

3

34.5

4

 

 

 

 

 

 

 

380

24,000

3

36.5

4

 

 

 

 

 

 

 

415

24,000

3

33.4

4

 

 

 

 

 

 

KW Volts Watts Ph Amps Wire

36

208

32,200

3

89.5

3

 

220

36,000

3

94.6

3

 

240

36,000

3

86.7

3

 

440

30,200

3

39.7

3

 

480

36,000

3

43.4

3

 

600

36,000

3

34.7

3

 

360

32,200

3

51.7

4

 

380

36,000

3

54.8

4

 

415

36,000

3

50.1

4

48

208

42,900

3

119.2

3

 

220

48,000

3

126.1

3

 

240

48,000

3

115.6

3

 

440

40,300

3

52.9

3

 

480

48,000

3

57.8

3

 

600

48,000

3

46.2

3

 

360

42,900

3

68.9

4

 

380

48,000

3

73.0

4

 

415

48,000

3

66.9

4

 

WATER C

DRAINAGE

 

 

CLEARANCE

 

D

 

 

 

 

 

 

 

 

1/4˝ NPT , Cold Water

The Floor Drain must be located

Right - 3”, Left - 3”, Rear - 3”

Inlet, 35 psi minimum,

outside the confines of the

(12” on control side if

60 psi maximum

equipment base.

adjoining wall or equipment

is over 30” high for service

 

 

1/4" NPT hot

1 1/2˝ I.P.S. common drain.

 

 

acess)

 

 

 

 

and cold water

 

 

Do not connect other units to this drain.

Contact factory for

 

 

for swing spout

 

 

Do not use PVC pipe for drain.

variances to clearances.

 

 

 

 

 

 

 

 

 

 

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA.

(NOT TO SCALE) SECT. III PAGE 18 0707

Litho in U.S.A.

Page 2
Image 2
Cleveland Range 42-CKEM-48, 42-CKEM-36, 42-CKEM-24 Water Quality Requirement, Electric, Water C, Drainage, Clearance