Cleveland Range C9797-K2PF specifications Technical Data, Prefilter

Models: C9797-K2PF

1 2
Download 2 pages 53.85 Kb
Page 2
Image 2
Prefilter

5.16”

31mm

nletI

4”3/ FNPT

22.44” 0mm5

.50”20

521mm

Outlet to Cmbio

venOmer- Stea

25.50”

521mm

Prefilter

Kleensteam II

Technical Data

Overall Dimensions:

25.5”H x 20.5”W x 7”D

 

 

Inlet Connection:

3/4” FNPT

 

 

Outlet Connection:

3/4” FNPT

 

 

Service Flow Rate:

Maximum 3.5 gpm (13.2 Lpm) - twin cartridges

 

 

Pressure Requirements:

10 - 125 psi (0.7 – 8.6 bar), non-shock

 

Maximum Water Temperature at Inlet: 100°F (38°C)

 

 

Alkalinity Range:

2 to 12 grains per gallon

 

 

Electrical:

No electrical connection required

 

 

Shipping Weight:

34 lbs.

 

 

Operating Weight:

42 lbs.

 

 

The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts.

NSF Certified under NSF/ANSI Standard 42 for materials

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

SECT. IIB PAGE 13

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers.

0707