![Prefilter](/images/new-backgrounds/68883/688833x1.webp)
5.16”
31mm
nletI
4”3/ FNPT
22.44” 0mm5
.50”20
521mm
Outlet to Cmbio
venOmer- Stea
25.50”
521mm
Prefilter | Kleensteam II |
Technical Data
Overall Dimensions: | 25.5”H x 20.5”W x 7”D |
|
|
Inlet Connection: | 3/4” FNPT |
|
|
Outlet Connection: | 3/4” FNPT |
|
|
Service Flow Rate: | Maximum 3.5 gpm (13.2 Lpm) - twin cartridges |
|
|
Pressure Requirements: | 10 - 125 psi (0.7 – 8.6 bar), |
| |
Maximum Water Temperature at Inlet: 100°F (38°C) | |
|
|
Alkalinity Range: | 2 to 12 grains per gallon |
|
|
Electrical: | No electrical connection required |
|
|
Shipping Weight: | 34 lbs. |
|
|
Operating Weight: | 42 lbs. |
|
|
The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain filterable cysts.
NSF Certified under NSF/ANSI Standard 42 for materials
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted. | SECT. IIB PAGE 13 |
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. | |
Cleveland Range equipment is built to comply with applicable standards for manufacturers. | 0707 |