F
E
D
C
B
A
1 2 34 5 6 78
F
E
D
C
B
A
1 2 34 5 6 78
CLEVELAND RANGE, LLC
1333 East 179th St., Cleveland, Ohio 44110-2574
VOLTAGE:
WATTAGE:
CURRENT:
DATE
SHEET OF
REV
DRAWN BY DRAWING NO.
THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE.
TITLE
SIZE
B
WIRING/LADDER DIAGRAM
OEB 6.20/10.10
300491
3Ø 208-240
15.8-20.7KW
45.5-51.8A
DRL
6-24-05 77
B
CLEANING PRESSURE SWITCH
DOOR MAGNET SWITCH
-Q56
-Q57
11
-K56
22
-K55
-K10
-K44
-Y23
-Y22
-Y21
-Y20
-K10
-K11
14
12
-K0-K10
-K11
-M4
-K2
-K55
-K57
-K5
-K50
5
FREE
4321
X14:
L1
FREE
10
9
76
10 98
L2
8
7
6
5
PUMP / CLEAN AGENT
X13:
3
1
34
COMPARTMENT RINSE V.
PUMP / RINSE
21
2
-K11
-B11
24
22 21
11
-B7.1
22
14
11
-B7.2
2
SAFTEY CONTACTOR
21
22
M
-K44
321
HOT AIR
STEAM GEN
781
STEAM GEN PUMP
RD
BU
-B1
H
L
9
21
21
22
22
21
-K56
-K57
6
87 54
56
X11:
MOTOR / SLOW
MOTOR / FAST
21
21
22
22
-K5
-K50
14 13 12 11 10
3
24
MOTOR / LEFT
MOTOR / RIGHT
MOTOR OVER TEMP
P>
-S2
-X10
13
-S7
156
157
14
14 13
-K1
-K4
14
13
-Y2
-K1
X1
X2
-H5.1
(RTN) 12VDC
L1 O
L2 12
3
IDENTIFICATION MODULE
8
X12:
-B6
PROBE OVEN
21
22
21 22
-K2
-Y3
-M1
13
TEMP SWITCH
14
1
2
1
7
GEM FILL/VALVE
MOTOR OVER TEMP
21
22
-Y1
-K4
3
54
76
X16:
STEAM GEN
HOT AIR
56
4
3
CONDENSOR/VALVE
DEHUMIDIFICATION/VALVEGN/RD
GN/BU
-B10
KTM
CTC
GN
GN
WH
GN
YL
21
-F2.1
12 10
11 9
OVEN LAMP
12
L1- 2O8/240-INPUT
4
3
12
BU
RD
WH
BK
21
IDM (W)
IDM (BL)
IDM (R)
IDM (BK)
RESET
10
91
1
1
2
8
-B5
-B3
PROBE BYPASS
PROBE CONDENSER
YL
RD
RD
YL
RD
(TEMP PROBE)
STEAM GENERATOR
-B4
RD
YL
X19:
-A13
4
7
86
5
X17:
TxD
7
0VDC IN
GND
45
X10:
6
RxD
M
-M3.1
110 9
-A10
X18:
12VDC+ FAN (COOLING)
12VDC- FAN (COOLING)
12VDC IN
13
2
(OPTION)
-B8
OVER TEMPERATURE
STEAM GEN.
ELEMENT (PROBE)
YL
RD
PICTO
-A12
MODULE
1
SM 5010
CONTROL BOARD
OPERATION BOARD
BM 5010
X39: 1
-A11
X15:
+5VDC
+5VDC
0VDC
0VDC
LADDER DIAGRAM
CLEANING OPTION ONLY
76