Cleveland Range OES-12.20 specifications Saves energy Automatic moisture level adjustment

Models: OES-12.20

1 2
Download 2 pages 15.21 Kb
Page 2
Image 2
The "Advanced Closed System" offers the following advantages:

 

 

48.51"

 

2.52"

1.58"

2.80"

 

 

 

56.15"

46.70"

 

 

 

9.06"

 

 

FRONT VIEW

 

3.39"

13.08"

AV

 

41.54" S

2.80"

TOP VIEW

2.80" ■Saves energy

■Low heat and steam emission to the kitchen 12.68"■Automatically regulated steam injection

31.50"

 

 

 

3.08"

42.29"

3.15"

 

 

 

14.26"

 

6.50"

27.29"

25.79"

18.90"

D

29.57"

 

 

2.96"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W1

 

1.19"

 

RC

 

W2

 

 

 

 

5.48"

 

 

 

 

 

 

 

CS

 

 

 

 

 

 

3.00"

BOTTOM VIEW

 

 

 

 

4.97"

 

 

 

 

 

 

10.87"

 

NOTES:

The "Advanced Closed System" offers the following advantages:

Saves energy

Automatic moisture level adjustment

Low heat and steam emission to the kitchen

Automatically regulated steam injection

Enables immediate change into the steam mode

"Crisp & Tasty" demoisturizing function

Model:OES-12.20

Pan Capacity [Unit (trolley) has 12 slide rails at 2.64" (67mm) apart]:

12

(20" x 26") full size wire racks

12

(18" x 26") full size sheet pans - on wire racks

24

(13" x 18") half size sheet pans - on wire racks

24

(12" x 20" x 2 1/2") steam table pans

24

(12" x 20" x 1") steam table pans

24

(12" x 20") frying baskets - (no wire racks needed)

 

 

 

 

For Banquet Operations: Optional Plate Rack holds 74 plates

Unit Dimensions: Width - 53.83", Depth - 44.34", Height - 57.73"

Shipping Dimensions: Width - 60", Depth - 50", Height - 66" (including packaging)

Shipping Weight:

717 Lbs (including trolley)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Agency Approvals: UL, UL - Sanitation (NSF Standards)

 

Electrical Requirements:

208/3/60

 

240/3/60

 

440/3/60

 

480/3/60

 

 

 

Total Connected Load:

26.3 KW

 

34.9 KW

 

29.4 KW

 

34.9 KW

 

Hot Air:

25.8 KW

 

34.3 KW

 

28.8 KW

 

34.3 KW

 

Amps per Phase:

77.8

 

88.8

 

41.4

 

44.9

 

 

 

 

 

 

 

 

 

Do not connect to a G.F.I. outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

 

 

 

 

Flow Pressure:

30 - 60 PSI

 

 

 

 

 

 

 

 

Water Inlets:

3/4" GHT-F (Female Garden Hose Connection)

 

 

 

W1

Treated Water for Steam Production

 

 

 

 

 

 

 

W2

Untreated Water for Condenser and Hand Shower

D

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain Connection:

2" Tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

 

 

 

 

 

 

 

Air Vent

 

 

 

 

 

 

 

 

 

 

AV

 

 

 

 

 

 

 

CS

 

 

 

 

 

 

 

 

 

 

 

 

 

*Connection for Cleaning Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RC

 

 

 

 

 

 

 

 

 

 

 

 

 

*Connection for Rinse Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLow Pressure Safety Valve *Available as an option

Cleveland Range reserves right of design improvement or modification, as warranted.