Cleveland Range OES-6.20 Front View, Top View, Bottom View, Shipping Weight, 485 Lbs, Venting

Models: OES-6.20

1 2
Download 2 pages 18.86 Kb
Page 2
Image 2
FRONT VIEW

 

 

47.92"

 

 

2.52"

1.58"

1.82"

 

 

 

36.12"

30.12"

 

 

 

6.00"

 

 

FRONT VIEW

 

3.39"

10.79"

AV

 

S

40.44"

2.80"

TOP VIEW

2.80"

TOP VIEW 12.68"BOTTOM VIEW

31.50"

 

 

3.23"

41.42"

3.27"

 

 

14.26"

 

6.93"

27.29"

21.19"

D

29.61"

 

2.96"

 

 

 

 

 

 

 

 

 

 

 

W1

 

1.19"

RC

 

W2

 

 

 

3.90"

 

 

 

 

 

CS

 

 

 

 

 

3.00"

BOTTOM VIEW

 

 

 

4.97"

 

 

 

 

 

10.87"

 

NOTES:

The "Advanced Closed System" offers the following advantages:

Saves energy

Automatic moisture level adjustment

Low heat and steam emission to the kitchen

Automatically regulated steam injection

Enables immediate change into the steam mode

"Crisp & Tasty" demoisturizing function

Model:OES-6.20

Pan Capacity [Unit has 7 slide rails at 2.64" (67mm) apart]:

7 (20" x 26") full size wire racks

7 (18" x 26") full size sheet pans - on wire racks

14

(13" x 18") half size sheet pans - on wire racks

14

(12" x 20" x 2 1/2") steam table pans

14

(12" x 20" x 1") steam table pans

14

(12" x 20") frying Baskets - (no wire racks needed)

 

 

 

 

For Banquet Operations: Optional Plate Rack holds 42 plates

Unit Dimensions: Width - 52.26", Depth - 43.24", Height - 36.82"

Shipping Dimensions: Width - 58", Depth - 49", Height - 45" (including packaging)

Shipping Weight:

485 Lbs

 

 

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Agency Approvals: UL, UL - Sanitation (NSF Standards)

 

Electrical Requirements:

208/3/60

 

240/3/60

440/3/60

480/3/60

 

 

 

Total Connected Load:

16.4 KW

 

21.6 KW

18.5 KW

22 KW

 

Hot Air:

14.7 KW

 

19.6 KW

16.5 KW

19.6 KW

 

Amps per Phase:

45.5

 

51.8

24.2

26.4

 

 

 

Do not connect to a G.F.I. outlet

 

 

 

 

 

 

 

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

 

 

 

Flow Pressure:

30 - 60 PSI

 

 

 

 

 

 

Water Inlets:

3/4" GHT-F (Female Garden Hose Connection)

 

 

 

W1

Treated Water for Steam Production

 

 

 

 

 

 

W2

Untreated Water for Condenser and Hand Shower

D

 

 

 

 

 

 

 

 

 

 

 

Drain Connection:

2" Tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

 

 

 

 

 

Air Vent

 

 

 

 

 

 

 

 

AV

 

 

 

 

 

CS

 

 

 

 

 

 

 

 

 

 

*Connection for Cleaning Solution

 

 

 

 

 

RC

 

 

 

 

 

 

 

 

 

 

 

*Connection for Rinse Cycle

 

 

 

 

 

 

 

SLow Pressure Safety Valve *Available as an option

Cleveland Range reserves right of design improvement or modification, as warranted.

SECT. IIA PAGE 36