Mode Functions

Operation

Five (5) Call Tone Settings

You can choose between five (5) different Call Tone Settings to transmit a unique call alert.

Mode/Power Button To Change A Call Tone Setting:

1.Press the Mode/Power button until the letter “C” and the current call tone number (01 through 05) is displayed. The current call tone will sound for one (1) second.

Call Tone Setting

2. Press the Channel Up or Channel Down button to hear the other call tone settings.

3. Choose one (1) of the following: a. Press the Mode/Power button to

Channel Button

enter the new setting and proceed to other functions.

b. Press the Lock button to enter the new

setting and return to Standby mode.

Roger Beep Confirmation Tone

Your listener will hear an audible tone when you release the Talk button. This alerts the other party that you are finished talking and it is OK for them to speak.

Mode/Power Button To Turn Roger Beep On Or Off:

 

1.

Press the Mode/Power button until the

 

 

 

Roger Beep icon flashes. The current

 

 

 

On or Off setting is displayed.

 

2.

Press the Channel Up or Channel Down

Roger Beep Off

 

 

button to select roger beep On or Off.

 

 

 

 

3.

Choose one (1) of the following:

 

 

 

a. Press the Mode/Power button to enter the

new setting and return to Standby mode.

Channel Button

b. Press the Lock button to enter the new

setting and return to Standby mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Introduction

Operation

 

 

 

Customer Assistance

Warranty

 

 

General Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

 

 

B. Receiver

 

Unit

Nominal

 

A. FRS/GMRS

 

 

 

 

 

 

 

 

 

 

 

Allocation and

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Sensitivity

 

 

 

 

 

Compatibility

 

 

 

 

 

 

 

 

 

 

 

For 12 dB SINAD

dBm

-121

 

Important: Please note that Cobra®

 

 

 

 

. . .For Call Signal Detection

.

-121

 

 

 

2.

Max. Audio Output

 

 

 

 

GMRS models with 15 Channels may

 

 

 

 

 

 

@ 10% THD

mW

200

 

designate different channel numbers for

 

 

 

3.

Max. S/N Ratio

 

 

 

 

the same frequency. For example, a

 

 

 

 

 

 

 

 

 

 

@ 1mV RF Input . . .

 

. dB

50

 

Cobra® 15 Channel GMRS model would

 

 

 

need to be tuned to Channel 11 in order

4.

Squelch

 

 

 

 

to communicate with a 22 Channel GMRS

 

 

a) Sensitivity

dBm

-121

 

tuned to Channel 15. Please refer to the

 

 

b) Attack Time

. mS

150

 

chart below for channel/frequency

 

 

 

 

c) Closing Time

. mS

200

 

number compatibility.

 

 

 

5.

Audio Frequency Response

 

 

 

 

A = Channel No. For

 

 

 

 

 

@ 300 Hz

. dB

-10

 

 

 

 

 

 

@ 2500 Hz

 

. dB

-10

 

 

22 Channel GMRS Models

 

 

 

 

 

 

 

 

6.

Signal Displacement BW

+/-kHz

5

 

B = Channel No. For 15 Channel

 

 

 

 

GMRS Models

 

 

 

7.

Adjacent Channel Rejection .

.

. dB

40

 

C = Type of Radio Service

 

 

8.

Intermodulation Rejection . .

.

. dB

65

 

D = Frequency in MHz

 

 

 

9.

Spurious Response Rejection

 

. dB

55

 

E = Power in Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C. Transmitter

 

Unit

Nominal

 

A

B

C

D

E

 

 

 

 

1

1

FRS/GMRS

462.5625

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

2

FRS/GMRS

462.5875

1.0

 

1.

Power

 

 

 

 

3

3

FRS/GMRS

462.6125

1.0

 

 

 

. . . . . .GMRS

.W

1

 

4

4

FRS/GMRS

462.6375

1.0

 

 

 

. . . . . . . . . . . . . . . . .FRS Only

500

 

5

5

FRS/GMRS

462.6625

1.0

 

2.

. . .Carrier Frequency Stability

500

 

6

6

FRS/GMRS

462.6875

1.0

 

3.

. . . . . . . .Modulation Limiting

 

7

7

FRS/GMRS

462.7125

1.0

 

4.

. . . . . . . . .Carrier Attack Time

80

 

8

 

FRS

467.5625

0.5

 

5.

Audio Frequency Response

 

 

 

 

9

 

FRS

467.5875

0.5

 

 

 

. . . . . . . . . . . . . . . .@ 300 Hz

. dB

-12

 

 

 

 

 

@ 2500 Hz

 

dB

+6

 

10

 

FRS

467.6125

0.5

 

 

 

 

11

 

FRS

467.6375

0.5

 

6.

. . . . . . . . . . . .Audio Distortion

 

 

 

7.

Hum Noise

 

dB

30

 

12

 

FRS

467.6625

0.5

 

 

13

 

FRS

467.6875

0.5

 

8.

Transient Frequency Behavior

 

mS

30

 

 

 

 

 

a) TX On

 

 

14

 

FRS

467.7125

0.5

 

 

 

 

 

 

 

 

b) TX Off

 

. mS

5

 

15

11

GMRS

462.5500

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

8

GMRS

462.5750

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

Nominal

 

17

12

GMRS

462.6000

1.0

 

 

D. Power Supply

 

 

 

 

 

 

 

 

18

9

GMRS

462.6250

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

13

GMRS

462.6500

1.0

 

 

 

 

 

 

 

 

 

1.

Battery Life (5:5:90 RATIO)

 

 

 

 

20

10

GMRS

462.6750

1.0

 

 

 

 

 

21

14

GMRS

462.7000

1.0

 

 

 

. . . . . .With Alkaline Batteries

. HR

24

 

 

2.

Battery Operating Range

 

V

4.2 - 6.0

22

15

GMRS

462.7250

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 English

Nothing comes close to a Cobra® 13

Page 9
Image 9
Cobra Electronics PR245 owner manual Power Supply