Applicable to Models: CFD-1F,  CFD-2F,  CFD-3F 
ColdTech® Freezer Settings
Temperature set to   | 
  | 
  | 
  | |
Parameter | Function  | Set Range  | Default  | |
E1  | Lower Setpoint Limit  | |||
E2  | Higher Setpoint Limit  | set temp ~ 120 F  | 20 F  | |
E3  | Hysteresis, temp variance  | 1  | ~ 18 F  | 10 F  | 
E4  | Comp. start delay time  | 0  | ~ 10 min.  | 3 min.  | 
E5  | Offset on room temp  | 0 F  | ||
E6  | Offset on evap temp  | 0 F  | ||
F1  | Max. defrost duration  | 1  | ~ 60 min.  | 30 min.  | 
F2  | Defrost interval time  | 0  | ~ 24 hr.  | 6 hr.  | 
F3  | Defrost termination temp  | 32 ~ 68 F  | 68 F  | |
Key
F = Farenheit (degrees)  | temp = temperature  | 
min. = minutes  | max = maximum  | 
hr. = hours  | N/A = not applicable  | 
Warning:
Do not change the default settings of your ColdTech unit without consulting a qualified service technician or the ColdTech service department.