AlphaServer 800 Pedestal–Rackmount
Uninterruptable Power Supplies
Prestige 1250EXT
UPS offerings include EIA232 port for local or network monitoring and plug-in battery extension provisions to increase run time up to two hours. For complete protection, UPS products should be used with data line surge protectors and UPS monitoring software.
Solutions for Pedestal Systems
4N-AEABF-AAPrestige 1250EXT, 1250 VA/900W, 1 phase, 50/60 Hz, 120V 6-foot cord with 5-15P plug, (4) 5-15R receptacle, 9 minutes battery at full UPS load.
4N-AEABF-BFPrestige 1250EXT, 1250 VA/900W, 1 phase, 50/60 Hz, 200-240V in/out selectable. Uses system power cord for detachable IEC320 input connection at UPS. Includes (3) IEC320 10A output receptacles, (2) output jumpers with IEC320 connectors to system.
4N-AEABF-BBExtension pack for 120V 60 Hz models, up to four packs at 30 minutes per pack supported
4N-AEABF-BDExtension pack for 240V 50 Hz models, up to four packs at 30 minutes per pack supported
4N-AEAEO-PAHot-swap Power-Pass Module for 60 Hz UPS with (7) 5-15R Surge Protected outlets.
4N-AEAEO-PBHot-swap Power-Pass Module for 50 Hz UPS with (6) IEC320, 10A surge protected outlets.
4N-AEWAR-G1Prestige 5 year on-site exchange warranty upgrade (US only).
Rackmount UPS
UPS Model | Application | Type | Receptacle module |
4N-AEAAH-FA | 60Hz Rackmount UPS, supports up to 5 systems | 3kVA Custom RM1 | Included2 |
4N-AEAAH-FB | 50Hz Rackmount UPS, supports up to 5 systems | 3kVA Custom RM1 | Included |
4N-AEAAJ-CL3 | 60Hz Out of Cabinet UPS | 6kVA Prestige4 | Included |
4N-AEAAJ-CU | 50Hz Out of Cabinet UPS | 6kVA Prestige4 | Hardwired |
1.Factory installation must be specified at time of order. Up to two UPS systems, one UPS for up to 5 fully configured systems. Recommended UPS distribution option combines multiple UPS input plugs into a single L6-30P plug-in connection to simplify future UPS add-on. Order 4NAEAAH-FF 60 Hz; 4N-AEAAH-FG 50 Hz).
2.Includes six IEC receptacle strips for connection to IEC plugs in cabinet.
3.208-120/208V shown; order 4N-AEAAJ-CT for 240-120/240V models
4.Optional mobile stacker with seismic mounting provision for 6kVA Prestige (4N-AEACH-HD)
4N-AEAAJ-CLPrestige 6 kVA (4 kW), single phase, 60Hz, 208-120/208V, 6 ft. cord with L6-30P and (2) L6-30R,
(8)5-15R receptacle. Modular hot-swap design with 7 minute battery at full UPS load, extendible plug and play batteries and receptacle provisions. Substitute -CT for 240V 240/120V operation.
4N-AEAAJ-CUPrestige 6 kVA (4 kW) 50Hz package, single phase, 50Hz, 200-240V in/out selectable, hardwired input/output.
4N-AEWAR-G3/G4Prestige 5 year on-site exchange warranty upgrade for 4N-AEAAH-CM/CT. G4 provides on-site remedial and start-up service.
UPS Monitoring and Unattended Shutdown Software (for above UPS systems only) is included in ServerWORKS Kits shipping with all AlphaServers. Order Cable Kit separately.
4N-ONLIN-NTCable Kit for DIGITAL UNIX
4N-ONLIS-FECable Kit for OpenVMS
Network Management or multi system shutdown (via SNMP or ServerWORKS Manager) for DIGITAL UNIX and OpenVMS requires Network Adapter option.
60 Hz Applications | 50 Hz Application | Network Adapter Option |
4N-AEAEO-DB/DD | 4N-AEAEO-DB/DD | Prestige 3 kVA RM, DB=Twisted pair; DD=ThinWire |
4N-AEAEO-DA/DC | 4N-AEAEO-DB/DD | Prestige 6 kVA and PUPS Plus UPS, DA/DB=Twisted pair; DC=ThinWire |
Note: Multiple system shutdown via OpenVMS requires multi-port hardware option (RN-JMIU4-AB). Ports can be daisy chained.