DWZZH 16-Bit UltraSCSI HUB (Rack-Mountable)
1.3Product Specifications
Table 1-1 lists the functional specifications for the DWZZH Hub.
Table 1–1 UltraSCSI Hub Functional Specifications
Feature | Specification | ||
SCSI ID | The small UltraSCSI Hub does not use a SCSI ID. | ||
SCSI Addresses | The large UltraSCSI Hub uses SCSI ID 7 for arbitration, | ||
| when the fair arbitration option is enabled. | ||
Overload Protection | TERMPOWER is not supplied by the UltraSCSI Hub. | ||
DTERMPOWER | Internal TERMPOWER is protected via a resetable fuse. | ||
STERMPOWER | TERMPOWER must be supplied from the remote | ||
| connection to enable | ||
| each Hub port. | ||
Shielding, Enclosure & | Shielded for ESD, EMI, and safety requirements. | ||
Connectors | |||
|
| ||
Automatically clears: | |||
| ∙ | Initiator detection circuit | |
| ∙ | Target detection circuit | |
| ∙ | BSY glitch filter | |
SCSI Bus Reset | Automatically clears: | ||
| ∙ | Initiator detection circuit | |
| ∙ | Target detection circuit | |
| ∙ | BSY glitch filter | |
Differential SCSI Bus | 25 meters (82 feet) per segment. Refer to Chapter 2, | ||
Length | Section 2.2 Configuration Note for more information | ||
Ultra (20 megatransfers | regarding cabling distances. | ||
per second or 40 MB/s) |
|
| |
Data Timing | The relationship between the data and the control | ||
| signals is brought to SCSI compatibility before | ||
| transmission to the other SCSI bus. | ||
Design | High reliability SMT |