Compur Statox 501 IR LC - Infrared detection of combustible gases.

The Statox 501 IR LC sensor head consists of an increased safety (EEx e) terminal box and a sensor with integrated electronics. The sensor operates with IR absorption principle. The supply voltage required is the same as for a catalytic sensor. Its signal output is also identical to a catalytic sensor, therefore it can be directly connected to the 501 Controller.

The important technical advantages of an infrared gas detector are now available for almost the same low price as a catalytic gas detector. The big advantage: As this product has the same energy requirements and signal output as common gas detection systems, the Statox 501 IR LC can be used to upgrade existing systems wherever the catalytic sensor did not do the job.

The Statox 501 IR LC it is a reasonable alternative to catalytic sensors wherever gas detection equipment is used to monitor hydrocarbons. The standard ex works calibration is Methane.

Technical data

 

 

Detectable gases

Hydrocarbons

 

Measuring range

0 – 100 % L.E.L. Methane

 

Measuring principle

IR- absorption, NDIR 2-channel

 

Detection limit

2 % L.E.L. Methane

 

Response time

t90 < 30 s

 

Operating temperature

- 20 to + 60°C

 

Humidity

0 – 95 % r. H.

 

Pressure

700 – 1300 hPa

 

Power supply

3 - 5,0 V DC

 

Current consumption

app. 80 mA

 

Connection

3 –wire

 

Operation

with Statox 501 Controller or

 

 

comparable supply

 

Weight

0,58 kg

 

Dimensions

110 x 130 x 60 mm HxWxD

 

 

(4,3 x 5,1 x 2,4 in.)

 

Material

Die cast aluminum, coated

 

Protection class

IP 54

 

Ex approval

EEx de IIC T4

Statox 501 Controller

Compur Monitors GmbH & Co. KG

Weissenseestraße 101

D-81539 München

Tel.: 089/62038-268

Fax: 089/62038-184

Email: compur@compur.de

Internet: http://www.compur.com

Specifications are subject to change without notice, and are provided only for comparison of products. The conditions, under which our products are used, are beyond our control. Therefore, the user must fully test our products and/or information to determine suitability for any intended use, application, condition or situation. All information is given without warranty or guarantee. Compur Monitors disclaims any liability, negligence or otherwise, incurred in connection with the use of the products and information. Any statement or recommendation not contained herein is unauthorized and shall not bind Compur Monitors. Nothing herein shall be construed as a recommendation to use any product in conflict with patents covering any material or device or its use. No licence is implied or in fact granted under the claims of any patent. Instruments are manufactured by Compur Monitors GmbH & Co. KG, Munich.