CONAIR
05-15-96 79 11
6.4 Trouble-shooting
6.4.1 If the granulator does not start
Check that the saftey switches’ break screws are turned fully clockwise. It is
not possible to start the granulator unless the break screws are screwed in.
Check that the emergency stop is not activated. It can be reset by turning the
button in the direction of the arrow.
The bimetal relay F1 in the electrical cabinet,
according to the diagram opposite, is
released if you press stop or overload the
granulator. This is indicated by the small
green rectangular pin (P), which sticks up
above the surface of the bimetal relay. When
you reset by pressing the "Reset" button, the
pin (P) is pushed back in so that it is level
with the surface of the bimetal relay.
NOTE: Set the main circuit-breaker to position "0" when cleaning the
granulator. Empty the granulator of all material before restarting it.
P
6.3 Cleaning
Always take great care when handling the knives since they are
very sharp and can cause personal injury.
1. Open the hopper and screenbox as
described in chapter 5.2.
2. Clean the hopper, flaps, screen and
screenbox and granule bin.
3. Clean the cutter-housing and inside the
stand.
4. Replace all parts in reverse order.
NOTE: When mounting the screenbox the
link screws' nuts (A) must be tightened quite
hard to avoid only one of the link screws
taking the whole load.
Note: Steps 2 - 4 should be carried out every time the machine is cleaned,
or at least once every 300 hours.
A