To replace an end gasket:
1 Remove the retaining rings. Loosen the wing nuts and lift off the ring that holds the gasket in place.
2 Remove the damaged gasket and slide a new gasket over the studs. No sealant is required.
3 Reassemble. Slip the retaining ring over the studs to cover the gasket. Tighten the wing nuts.
REPLACING GASKETS
Normal operation of the WT/ST tank creates many wet sur- faces. We recommend generous monthly lubrication of any threaded or sliding components involved in positioning the tank. Those components include the positioning mechanisms such as the up/down vertical support shafts,
1 Lubricate the vertical support shaft and grease fittings. Apply bearing compound to the fit- tings until it overflows. Apply a coating of the compound to the shafts as well.
2 Lubricate the
LUBRICATING
THE TANK
COMPONENTS
Tools required:
❒grease gun
❒
3
Lubricate the linear actuator according to manufacturer’s instructions.
The tank, spray bars and optional recirculation reservoir should be thoroughly to remove particles that can accumulate.
1 | Drain the tank and reservoir. |
|
|
2 | Wipe surfaces thoroughly to remove particles. |
3 Remove the spray bars. Twist each spray bar coun- terclockwise and pull it out.
4 Clean the spray bars. Flush each bar with a compressed air line or water hose. Use a soft brush to remove any particles clogging the small holes.
CLEANING THE
TANK AND
SPRAY BARS
5
Reassemble by repeating the steps in reverse order.
UGE014/0999 | Water/Spray Tanks | MAINTENANCE |